The AirTAC GFR60025MJF2WGK AirTAC Filter Regulator G1 (1 in) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR60025MJF2WGK is a size-600 filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in a single body. This configuration carries a G1 (1 in) G-thread port, a fine 5 um filter element (code W), a manual drain on the bowl, an embedded square gauge reading in psi, and a built-in reverse/check valve that holds downstream pressure when the upstream supply is lost. The 600-size bowl is aluminium alloy, and the unit is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with a choice of ports, PT/G/NPT threads, manual, automatic or differential-pressure drains, 40 um or 5 um elements, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR60025MJF2WGK AirTAC Filter Regulator G1 (1 in) |
|---|---|
| Series | GFR600 filter regulator |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · PT1" · 5 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-25 (two-unit set) |
Point-of-use water and particle removal plus a stable regulated supply for clamps, tool changers and actuators on a machining centre's 1 in main air drop.
Regulated, filtered air feeding pneumatic cylinders and diverters along a filling and conveyance line, with the check valve holding the circuit on a supply dip.
Filtered, regulated air for spray guns and coating equipment, where the unit's filter-regulate-only function keeps lubricant mist out of the finish.
Step up through sizes 200, 300, 400 and 600 as your port and air demand grow; this unit sits at the top of the range with a 1 in G-thread port. Choose the drain to match maintenance practice: manual (this unit, with the widest 0.05-0.9 MPa / 7-130 psi adjustment range), automatic, or the differential-pressure default. Pick the element grade: 40 um standard or 5 um (W) where finer protection matters - this unit carries the 5 um element. Gauge scale is selectable (MPa, psi or bar; this one is psi square), and thread is PT standard with G and NPT as order options. A bracket is optional; this configuration omits it.
Because AirTAC publishes flow as curves rather than one rated figure, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves rather than a single rated number, so we do not quote a figure here. Tell us your flow and working pressure and we will confirm the datasheet curve and correct sizing for your application on request.
The W in the code GFR60025MJF2WGK selects the optional 5 um filter grade instead of the 40 um standard. The finer element suits downstream equipment that tolerates less particulate. The manual drain (M) is the other key choice: it gives the widest 0.05-0.9 MPa (7-130 psi) adjustment range, but the bowl must be drained by hand.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.