AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um

The AirTAC GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$134.51 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um

The AirTAC GFR600C20AJC2WK is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built for a 3/4 in PT thread, carries a 5 um filter element (the finer optional grade; 40 um is standard), and drains condensate automatically, so the bowl does not need manual draining on a set schedule. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and an external round gauge scaled in psi is fitted so the set pressure is visible at the unit. A reverse/check valve is included to hold downstream pressure if the upstream supply drops. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). At size 600 the bowl is aluminium alloy.

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with a choice of ports, PT, G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge type and scale, and optional reverse/check valve. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application on request.

GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um Technical Specifications

ModelGFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um Is Used

factory

Main air preparation for a production line

Installed at the 3/4 in take-off feeding a plant floor of air tools and actuators, this unit cleans the supply to 5 um and holds a regulated working pressure, with automatic drainage keeping condensate off the distribution network.

precision_manufacturing

Pneumatic press and clamping fixtures

On a machining cell where clamps and a pneumatic press need a stable, repeatable set pressure, the psi-scaled gauge lets the setter dial in the clamping force, and the check valve holds the circuit if the main supply dips.

conveyor_belt

Conveyor and packaging machinery supply

Feeding the cylinders and air jets on a packaging or conveyor line, the 5 um element protects directional valves from particulate while the regulator keeps actuation speeds consistent, and the automatic drain suits equipment that runs unattended.

Is the GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um the Right Unit?

Size 600 with a PT3/4 port sits at the top of the GFR range, so start by matching the port and the expected air demand to your line size; if your consumption is well below what a 3/4 in line carries, a smaller GFR size may be the more economical choice. This unit already specifies the finer 5 um element - choose it where downstream valves, cylinders or instruments are sensitive to finer particulate; the standard grade is 40 um. The automatic drain suits installations that are not visited daily; a manual drain is the alternative where an operator is on site. The fitted round gauge reads in psi; MPa and bar scales are also available. PT is the standard thread, with G (BSPP) and NPT as order options, and this configuration is supplied without a mounting bracket.

Because flow for the GFR series is published as curves rather than a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm the datasheet and check the sizing against your required flow before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a flow number for this unit. Tell us your line pressure and the air demand of your equipment and we will confirm the datasheet flow curve and check the sizing for your application on request.

Both are decoded from the model code. The A position selects the automatic drain, which expels collected condensate without an operator, and the W position selects the optional 5 um filter element instead of the 40 um standard grade - a good choice when downstream valves, cylinders or instruments are sensitive to finer particulate. A manual-drain, 40 um version of the same size 600 unit is available if that suits your installation better.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20AJC2WK AirTAC Filter Regulator PT3/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20AJC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.