The AirTAC GR20006JF2 AirTAC Air Pressure Regulator PT1/8, psi gauge is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The GR20006JF2 is an AirTAC GR-series air pressure regulator: it does one job, holding a stable downstream pressure from a compressed-air supply. This 200-size unit carries a PT1/8 (1/8 in) port with PT thread as standard, adjusts across 0.05-0.9 MPa (7-130 psi), and tolerates a maximum inlet pressure of 1.0 MPa (145 psi). It is a standard-type regulator with no reverse/check valve, and it is fitted with an embedded square gauge reading in psi (MPa and bar scales are available as order options). Operating temperature is -20 to 70 C, wider than the rest of the G-series. It ships without a mounting bracket but is panel-mountable.
This is a genuine AirTAC part. The GR family spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, plus options including a low-pressure type (up to 0.4 MPa), a reverse/check valve, external round gauges and G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure against your application before ordering.
| Model | GR20006JF2 AirTAC Air Pressure Regulator PT1/8, psi gauge |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Supplied without bracket |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
On a small robotic pick-and-place head, the GR20006JF2 sets and holds the supply pressure to compact gripper cylinders, keeping grip force repeatable across thousands of cycles without manual re-adjustment.
At a machining-cell workbench, this regulator feeds clamping fixtures on a 1/8 in branch, letting the operator dial in a lower, safer clamp pressure than the main header while the square psi gauge shows the setpoint at a glance.
In a lab or pilot rig running air-driven instruments, the GR20006JF2 trims the branch pressure precisely within its 0.05-0.9 MPa range, and its -20 to 70 C rating suits unconditioned utility rooms.
Start with the port step: GR200 with its PT1/8 port suits the smallest branch lines, while GR300/400/600 step up in port and flow capacity - match the size to the air demand of the circuit rather than oversizing on guesswork. Set the downstream pressure inside the 0.05-0.9 MPa (7-130 psi) adjustment range; if your process runs below that, the GR low-pressure type (L) covers regulation up to 0.4 MPa. Choose the gauge scale to suit your team: this unit reads psi, with MPa and bar scales available. Thread is PT as standard, with G (BSPP) and NPT as order options, and a reverse/check valve can be specified if backflow protection is needed. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC publishes regulator flow as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and expected air demand, and we will confirm the correct size and the flow/datasheet figures for this model on request before you order.
The trailing F2 in the code specifies an embedded square gauge with a psi scale. MPa and bar scales are available as order options, and an external round gauge can be specified instead if you prefer. State the scale you want when ordering - it is a specification choice, not an add-on we fit later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.