verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GR200 · Air Pressure Regulator

GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8

The AirTAC GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8 is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/8"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadNPT
  • BracketSupplied without bracket
$29.75 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8

The AirTAC GR20006LJF2T is a GR-series air pressure regulator: it does one job, holding a stable downstream pressure from your compressed-air supply. This 200-size unit carries a 1/8 in NPT port and is the low-pressure type, adjustable up to 0.4 MPa, so it suits circuits that must never see full line pressure. It is fitted with an embedded square gauge scaled in psi, has no reverse/check valve, and is supplied without a mounting bracket; the GR body is also panel-mountable. As a regulator it has no filter element, no bowl and no drain, and it handles compressed air at up to 1.0 MPa (145 psi) inlet across a -20 to 70 C range.

This is a genuine AirTAC part. The GR family spans 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, standard or low-pressure adjustment, square or round gauges in MPa, psi or bar scales, an optional reverse/check valve, and PT, G or NPT threads. Because AirTAC publishes flow only as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.

GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8 Technical Specifications

ModelGR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8
SeriesGR200 pressure regulator
Port sizePT1/8" (NPT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8

GR200G-series pressure regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/8" · 0.05 - 0.4 MPa (7 - 58 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8 Is Used

tune

Packaging machine control circuit

Set a reduced, stable supply pressure feeding the control valves and small cylinders on a carton-sealing or wrapping machine, keeping actuator speeds consistent shift after shift.

science

Laboratory air supply drop

Step bench compressed air down to a gentle, repeatable pressure for lab apparatus and test rigs, with the psi-scaled square gauge giving a clear reading at the panel.

engineering

Pneumatic test bench

Provide adjustable low-pressure air to a workbench setup used for leak-checking or function-testing small pneumatic assemblies, where the circuit must stay well below full line pressure.

Is the GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8 the Right Regulator?

Start with the port step: the 200 size takes a 1/8 in port, and larger sizes (300/400/600) step up to 1/4 in through 1 in for higher air demand - match the size to the flow your circuit needs, then ask us to confirm the flow curve. Choose the regulator type next: this L-coded unit adjusts up to 0.4 MPa for low-pressure circuits, while the standard type covers 0.05-0.9 MPa. Decide the gauge scale (this one reads psi), the thread (PT is the standard, G and NPT are order options - this unit is NPT), and whether you want a bracket fitted (this unit ships without one; GR is also panel-mountable). If your line also needs water and particulate removal or oil misting, that is a different family - a GR regulates pressure only. Before ordering, send us your application details so we can confirm sizing against the published flow curves.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8 FAQ

AirTAC publishes regulator performance as flow curves rather than a single rated flow figure, so we do not quote a number here. Tell us your application and air demand and we will confirm the datasheet and the appropriate size on request before you order.

L marks the low-pressure regulator type: its adjustment range tops out at 0.4 MPa instead of the standard type's range, making it the right choice for circuits that must never be set above that level. The rest of the code decodes as 200 size, 1/8 in NPT port, no bracket, and a square gauge scaled in psi.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GR20006LJF2T AirTAC Air Pressure Regulator, NPT1/8