verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GR300 · Air Pressure Regulator

GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure

The AirTAC GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT3/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadNPT
  • BracketFixing bracket included
$35.61 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure

The GR30010LF1T is an AirTAC GR-series air pressure regulator, built purely for pressure regulation - it contains no filter, no bowl and no lubricator. This unit is the low-pressure type (L), with an adjustment range up to 0.4 MPa, in the 300 size with a 3/8 in NPT female port. It carries an embedded square pressure gauge with an MPa scale, and no reverse (check) valve is fitted. A mounting bracket is included, and the GR body is also panel-mountable. Maximum inlet pressure is 1.0 MPa (145 psi), and the GR series operates from -20 to 70 C, a wider temperature window than the rest of the G family.

This is a genuine AirTAC part. The GR series is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, in standard or low-pressure types, with gauge and thread options to order. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures against your application.

GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure Technical Specifications

ModelGR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure
SeriesGR300 pressure regulator
Port sizePT3/8" (NPT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure

GR300G-series pressure regulator, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR300 · PT3/8" · 0.05 - 0.4 MPa (7 - 58 psi)
One size downGR200
One size upGR400
Line orderFilter first, then regulator, then lubricator

Where the GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure Is Used

tune

Paint spray booth air supply

Dropping booth air to a gentle, stable pressure before atomising spray guns, where a low set point and a visible MPa gauge keep finish quality consistent across shifts.

view_module

Packaging machine low-pressure actuation

Feeding delicate sealing and folding actuators on a carton packaging line that run at reduced pressure, with the 3/8 in port serving a multi-drop drop from the main header.

air

Air knife and blow-off station

Regulating a low-pressure air knife or blow-off nozzle on a conveyor line, where the low-pressure type keeps delicate products and lightweight film from being disturbed.

Is the GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure the Right Regulator?

Start with the port step: the 300 size with a 3/8 in port suits lines where 1/4 in is too small, but the right step depends on the flow your circuit needs - flow is published as curves, not a single rating, so ask us to confirm sizing before ordering. Choose the low-pressure type (L) only when your set point stays at or below 0.4 MPa; for higher set points use the standard GR type. This unit ships as decoded with an NPT thread (PT is the AirTAC standard; G/BSPP and NPT are order options), a square gauge with MPa scale (psi or bar scales and an external round gauge are available), no reverse valve, and the bracket included - a no-bracket (J) variant exists if you panel-mount.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure FAQ

AirTAC publishes regulator flow as curves rather than a single rated number, so we do not quote a rated flow, Cv or l/min figure. Ask us and we will confirm the datasheet flow curve for the 300 size against your application before you order.

L marks the low-pressure regulator type, with an adjustment range up to 0.4 MPa. Choose it when your set point stays within that window; for higher set points, order the standard GR type instead. The rest of the code decodes as 300 size, 3/8 in NPT port, square gauge with MPa scale, and NPT thread.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GR30010LF1T AirTAC Pressure Regulator NPT3/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR30010LF1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.