AirTAC GR600 · Air Pressure Regulator

GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in)

The AirTAC GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadG (BSPP)
  • BracketSupplied without bracket
$58.43 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in)

The GR60025JF2G is an AirTAC GR-series air pressure regulator for compressed air, built in the largest 600 size with a G1 (1 in) G-thread port. It is a regulation-only unit: it steps supply pressure down to a stable working setting anywhere in its 0.05-0.9 MPa (7-130 psi) adjustment range, with a maximum inlet pressure of 1.0 MPa (145 psi). This configuration carries the standard embedded square gauge scaled in psi, and the J suffix means no mounting bracket is fitted; the GR body is also panel-mountable. Operating temperature is -20 to 70 C, wider than the rest of the G family.

This is a genuine AirTAC part from the GR regulator line, which spans 200, 300, 400 and 600 sizes with port options from 1/8 in to 1 in, standard or low-pressure regulation, gauge scale choices, an optional reverse/check valve, and bracket or no-bracket mounting. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in) Technical Specifications

ModelGR60025JF2G AirTAC Air Pressure Regulator G1 (1 in)
SeriesGR600 pressure regulator
Port sizePT1" (G (BSPP) thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in)

GR600G-series pressure regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR600 · PT1" · 0.05 - 0.9 MPa (7 - 130 psi)
One size downGR400
Line orderFilter first, then regulator, then lubricator

Where the GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in) Is Used

factory

Main air header regulation

Installed at the 1 in main drop feeding a plant-wide compressed-air ring, holding a steady header pressure for every downstream branch circuit.

precision_manufacturing

Pneumatic press station supply

Set ahead of a pneumatic forming or clinching press, giving the operator a fixed, repeatable working pressure for consistent clamping force.

conveyor_belt

Packaging line actuator control

Placed on the supply to carton-sealing and case-erector cylinders on a packaging conveyor, keeping actuator speed and holding force stable as demand varies.

Is the GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in) the Right Regulator?

Choose the GR size by the port and flow your line needs: this 600 unit takes a 1 in port, the largest in the range, so it suits high-consumption headers and main-line drops, while 200-400 sizes cover smaller branches. Set the downstream pressure anywhere in the 0.05-0.9 MPa (7-130 psi) range; if your circuit never exceeds 0.4 MPa, the low-pressure (L) variant of the GR is available. Pick the gauge scale you read on site - MPa, psi or bar - and the thread your piping uses: PT is the catalogue standard, with G (BSPP) and NPT as order options. Bracket (blank) or no bracket (J) is a mounting choice, and a reverse/check valve (K) can be specified if the circuit needs one.

Flow for this regulator is published as curves, not a single rating, so send us your air demand and supply conditions and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in) FAQ

AirTAC publishes regulator flow as curves rather than a single rated figure, so we do not quote one number. Tell us your supply pressure, set pressure and air demand, and we will confirm the sizing from the datasheet on request.

The F2 in the code specifies the embedded square gauge scaled in psi, and the J specifies no mounting bracket - the GR body can still be panel-mounted. Other gauge scales (MPa or bar), a round external gauge, bracket mounting and a reverse/check valve are all available as order options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GR60025JF2G AirTAC Air Pressure Regulator G1 (1 in)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR60025JF2G and will confirm price, stock and lead time — usually within 7-8 hours.