The AirTAC AirTAC 3V300M-13 3V-F Base (3V300M13F) is a genuine 3V-F manifold base manifold base for 13 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.
The 3V300M13F is a 13-station base for AirTAC 3/2 solenoid valves. Because all thirteen stations hang off one shared supply, a fault is found at the block rather than traced through a maze of individual feeds - and replacing a faulty valve means undoing one station, not re-piping a machine. Each mounted valve performs the standard 3/2 job of feeding or venting its outlet.
This base is a genuine AirTAC part and carries no coil of its own: no voltage, no state and no power draw belong to it. Those choices sit with the valves you order separately, which can be any mix of NC and NO, any of the five voltages and both entry styles; other station counts are available across the family. We confirm valve datasheet figures when you enquire.
| Model | AirTAC 3V300M-13 3V-F Base (3V300M13F) |
|---|---|
| Series | 3V-F manifold base |
| Item form | Manifold base (no coil, no solenoid, no initial state) |
| Stations | 13 |
| Port size | Confirm from the datasheet — ask us |
| Thread | PT |
| Operating pressure | Confirm from the datasheet — ask us |
|---|---|
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V-F manifold base | Body. |
|---|---|
| 13F | 13 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Weld and assembly fixtures use single-acting clamps that a 3/2 valve presses and a spring releases; a manifold keeps the cell tidy.
Pneumatic hold-downs along a saw or router table can run from individually valved stations sharing one block and one feed.
Benchtop rigs that actuate small test fixtures or divert sample lines can mount all their 3/2 valves on a single base.
Order the base for the number of stations you need now and can grow into, then order valves to fill it. Every valve you fit is an independent 3/2 choice: NC or NO according to what should happen on power loss, one of the five coil voltages according to the panel, DIN plug or flying lead according to the wiring. Maintenance is simpler on a manifold because one supply is isolated instead of many. What we cannot confirm from this page is flow - the figures for this family are not in our hands - so send the actuator details and we will size the valve from the datasheet. Where published figures are a hard requirement today, the 3V2 and 3V3 valve bodies are the documented route; for double-acting cylinders, specify the AirTAC 4V series.
Confirm before you order
On request we will pull the datasheet for the valve you name and confirm its operating pressure range, flow figure and coil power. This page itself publishes none of them. Buyers who cannot wait for a datasheet should note that the AirTAC 3V2 and 3V3 valve bodies carry published flow and coil-power figures.
Ask what must happen when power fails. A normally closed valve shuts the outlet and vents it, so a clamp stays safe; a normally open valve keeps the outlet fed, which suits processes that must continue through a power cut. Both are available for this base, ordered separately per station.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.