The AirTAC AirTAC 3V106A-15 Solenoid Valve, 3V1 Series (3V106A15F-AM) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Fifteen valves, one footprint: the 3V106A15F-AM mounts a full bank of 3V1 3/2 direct-acting valves on a common 1/8in PT manifold base, cutting the panel space fifteen separate bodies would need. Every valve is single-solenoid with spring return and a manual override; coils are AC220V at 4.5 VA each with IP65 (DIN 40050) protection.
The -AM suffix flags a variant of this assembly whose exact content is not covered here - confirm what it adds before ordering. In service, each station switches its own line between feed and exhaust, driving single-acting cylinders, clamps or blow duties; supply air should be filtered to 40 um or finer.
| Model | AirTAC 3V106A-15 Solenoid Valve, 3V1 Series (3V106A15F-AM) |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC220V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 4.5 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC220V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 15F | 15 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Presses a spring-return sealing jaw onto the tape flap of each shipping carton, venting the line so the jaw lifts clear as the box advances.
Energises in sequence to close pneumatic toggle clamps around a bracket, then dumps all clamp lines simultaneously at cycle end for fast unloading.
Releases one component at a time from a vibratory bowl by stroking a single-acting stopper pin, with spring return holding the gate shut when de-energised.
Because AirTAC publishes no Cv for 3V1, sizing is done by duty rather than datasheet flow figures - ask us when flow is critical. This 15-station manifold serves many light pilot and single-acting loads from one air supply; if a line needs more capacity, the 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4in, Cv 0.62) is the step up, while the 3V2M wins when dense manifolding matters more than flow. For a double-acting cylinder, switch to the AirTAC 4V series.
Confirm before you buy: M5 or 1/8in port; PT as the standard thread on this family with G and NPT as catalogue options to order; the coil voltage; DIN plug or flying-lead entry; and the number of stations - fifteen on this assembly, from a possible 1F to 20F.
Confirm before you order
Baseline figures: 0-0.8 MPa (0-114 psi) operating pressure, -20 to 70 C temperature range, 4.5 VA per AC220V coil, IP65 (DIN 40050) protection, and 15 stations on 1/8in PT ports. The catalogue carries no Cv for the 3V1 body, so confirm any flow-dependent choice with our team.
Each 3/2 station feeds or vents one line, which fits single-acting (spring-return) cylinders, on/off air blow, clamping and piloting a larger valve. It cannot drive a double-acting cylinder - that needs two working lines and a 5-port valve such as AirTAC's 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.