verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106A1F

The AirTAC Airtac 3V1 Solenoid Valve 3V106A1F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryDIN plug (DIN socket type)
  • Stations1
  • Series3V1
$25.47 $29.79Save 14% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106A1F

The 3V106A1F is one 3/2 direct-acting solenoid valve mounted on a single-station manifold base. Functionally it behaves like an individual valve: one AC220V solenoid switches the outlet between supply and exhaust, and the spring return makes the vented position the resting state whenever the coil is off. The coil draws 4.5 VA at 220 V AC - one of the lightest electrical loads you will put on a machine panel.

Because it sits on the same base system as the multi-station 3V1 assemblies, you can standardise on one valve style today and extend to a shared manifold later, with 1/8in PT ports and a DIN plug coil connection at IP65 (DIN 40050). A manual override is fitted for commissioning. Air should be filtered to 40 um or finer; no lubricator is needed.

Airtac 3V1 Solenoid Valve 3V106A1F Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106A1F
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryDIN plug (DIN socket type)
Coil power4.5 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106A1F

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
1F1 stations in one assembly.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106A1F Is Used

handyman

Bench-mounted air tool switching

On a maintenance bench, the valve routes shop air to a single fitting or vents it, with the manual override letting you actuate by hand before any wiring is done.

speed

Kicker cylinder on a labelling head

Drive the short-stroke kicker that presses a label onto a passing pack; the spring return pulls the kicker back the instant the coil de-energises between packs.

build

Prototype pneumatic rigs

Because the valve sits on the standard 3V1 base, a prototype rig can start with one station and grow into a shared manifold once the design is proven.

Is the Airtac 3V1 Solenoid Valve 3V106A1F the Right Part?

Think of the 3V106A1F as the entry point of the 3V1 manifold system: one valve now, up to twenty stations on the same family later. Note that AirTAC publishes no Cv for 3V1, so for flow-critical ports confirm the duty with us first. Where a single station needs more flow, move up to 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, rated for vacuum) or 3V3 (1/4in, Cv 0.62); 3V2M is the series to compare when packing many stations into a small panel is the priority. Driving a double-acting cylinder requires a 5-port valve - the AirTAC 4V series covers that.

Confirm five points before ordering: port (M5 or 1/8in), thread (PT standard on this family; G and NPT available as catalogue options), coil voltage, electrical entry (DIN plug or flying lead), and whether you want a single valve or a multi-station manifold.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106A1F FAQ

Pressure range 0-0.8 MPa (0-114 psi); temperature -20 to 70 C; IP65 (DIN 40050) coil protection; supply air filtered to 40 um or finer with no lubrication needed. The AC220V coil is rated 4.5 VA, with the wider 3V1 line at AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W and DC12V 2.5 W. AirTAC publishes no Cv or effective area for 3V1, so confirm flow-critical applications with us directly.

This code uses a DIN plug: the coil socket stays on the valve and you run a separate DIN connector cable to it, which keeps valve replacement simple. The same body is available with an I-suffix flying lead, where the wires leave the coil pre-wired - handy inside tight cabinets. Both entries meet IP65 (DIN 40050) and both keep the 4.5 VA AC220V coil, so the choice is purely about the wiring practice on your machine.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106A1F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106A1F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.