The AirTAC AirTAC 3V106B-12 Solenoid Valve, 3V1 Series (3V106B12F) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V106B12F is a twelve-station manifold assembly of AirTAC 3V1 direct-acting 3/2 solenoid valves. Each station feeds or vents one line - supply, outlet and exhaust - so it suits single-acting cylinders, clamps, air-blow nozzles or pilot duty on a larger valve. A single solenoid with spring return settles every valve back to its rest position when power drops.
Each coil runs on DC24V and draws just 3.0 W, so the whole bank of twelve stays gentle on a small 24 V power supply. Ports are 1/8in PT, the standard thread on this family, and every valve carries a manual override to help commissioning. The valves come in one fixed initial state - confirm it on the datasheet before wiring your panel.
| Model | AirTAC 3V106B-12 Solenoid Valve, 3V1 Series (3V106B12F) |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 12F | 12 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Twelve single-acting clamp cylinders retract by their own springs and clamp on air; one valve station per clamp keeps the jig panel tidy.
Each station pulses a jet of dry air to clear droplets before labelling; 3.0 W coils suit high-density 24 V control cabinets.
Compact 3/2 stations switch pilot signals to larger process valves, with the manual override handy during start-up checks.
Size in both directions before you commit. 3V1 is the smallest, lowest-power body in AirTAC's 3V range and publishes no Cv, so for flow-critical duties step up to 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, and rated for vacuum) or 3V3 (1/4in, Cv 0.62). If a dense bank matters more than flow, 3V2M is the manifold specialist. Double-acting cylinders are outside 3-port territory - point those jobs at the AirTAC 4V series.
Confirm five points when ordering this code: 1/8in port with PT thread (G and NPT are order options), DC24V coil, DIN plug entry, and a 12-station manifold rather than an individual valve. Air needs 40 um filtration or finer; lubrication is not required.
Confirm before you order
Operating pressure is 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C. Each DC24V coil draws 3.0 W; the 3V1 family also offers AC220V or AC110V at 4.5 VA, AC24V at 5.0 VA and DC12V at 2.5 W. Protection is IP65 (DIN 40050). No flow coefficient (Cv) or effective area is published for 3V1 - confirm any flow-critical duty with us.
Yes. Each station is its own 3/2 valve sharing a common air supply, so twelve single-acting cylinders, blow jets or pilot lines can be switched individually from 24 V controls. It cannot drive double-acting cylinders - that needs a 5-port valve such as AirTAC's 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.