The AirTAC AirTAC 3V106B-18 Solenoid Valve, 3V1 Series (3V106B18F) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V106B18F packs eighteen spring-return 3/2 valves onto a single manifold, each with a 1/8in PT port and a DC24V coil consuming 3.0 W. Because the valves are direct acting and single solenoid, they shift on coil power alone and fall back on the spring when power is cut - no pilot air needed and no latching between states. Typical jobs are venting a single-acting cylinder, switching a blow line or sending a pilot signal to a bigger valve.
Every station carries IP65 protection (DIN 40050) and a manual override for commissioning without power. Supply air through a 40 um or finer filter; the design needs no lubrication. Eighteen valves on one base replace a crowded panel of individual bodies and their separate plumbing.
| Model | AirTAC 3V106B-18 Solenoid Valve, 3V1 Series (3V106B18F) |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 18F | 18 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
An eighteen-station bank drives the spring-return pushers that kick defective packs off a checkweigher conveyor, one valve per lane.
Every station clamps and vents one single-acting swing clamp around a CNC pallet fixture, so all eighteen tooling points run from one manifold.
Operators trigger a blow nozzle that clears chips from a tapped housing before gauging; the exhaust port dumps the line the moment the coil drops.
As the most compact and lowest-power 3V body, the 3V1 wins on space and coil draw, and the 18F format multiplies both savings across eighteen stations. When a function needs more flow than 3V1 can be proven to give - remember, no Cv is published - move up to 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4in, Cv 0.62); for sheer manifold density, 3V2M is the alternative body. Confirm before ordering: M5 or 1/8in port; PT as the standard thread with G and NPT orderable; your exact coil voltage; DIN plug or flying lead; and how many stations you need. Driving a double-acting cylinder? That requires the 5-port AirTAC 4V series.
Confirm before you order
Pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 to DIN 40050, DC24V coil at 3.0 W, 40 um filtration required, and no published Cv for the 3V1 body. Family coil powers for reference: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC12V 2.5 W.
At 3.0 W per coil, the whole assembly draws only 54 W with all coils energised, which is gentle on small 24 V power supplies and keeps DIN plug wiring simple. Each station still works as an independent 3/2 valve - feeding or venting one line for single-acting cylinders, blow duties or pilots. Double-acting cylinders need the 5-port AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.