
The AirTAC Airtac 3V1 Solenoid Valve 3V106BI3F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V106BI3F is a three-station manifold of AirTAC 3V1 valves: three 3/2 direct-acting units sharing one PT1/8 base, each coil DC24V at only 3.0 W and each wired through a pre-fitted flying lead instead of a DIN socket. Every station feeds or vents a single line - supply, outlet, exhaust - so it can drive a spring-return cylinder, run a blow jet, switch a clamp or pilot a larger process valve, then spring back the moment the coil drops out.
Putting three valves on one block saves panel space and fitting count compared with three separate bodies. Coil housings are IP65 (DIN 40050), a manual override on each station speeds commissioning, and the air supply needs only 40 um or finer filtration with no lubrication. Each valve is supplied in a single fixed initial state - confirm it on the datasheet. We supply genuine AirTAC.
| Model | Airtac 3V1 Solenoid Valve 3V106BI3F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 3F | 3 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Three stations in one block pilot larger diaphragm rinse valves on a bottle filler, with the DC24V 3.0 W coils switching straight from PLC outputs.
Each station feeds a single-acting spring-return clamp cylinder on a drilling jig, so clamps vent automatically if power fails.
Three short air pulses eject finished micro parts from an inspection nest, one jet per valve, powered at just 3.0 W per coil.
3V1 is the smallest, lowest-power body in the AirTAC 3V range, and no flow coefficient is published for it - so for flow-critical duties confirm sizing with us first. If a single circuit needs more flow, step up to 3V2 (1/8 in and 1/4 in ports, selectable NC or NO, Cv 0.18-0.19, rated for vacuum) or to 3V3 (1/4 in, Cv 0.62). When manifold density matters more than flow, 3V2M is the purpose-built alternative. Need to drive a double-acting cylinder? That takes a 5-port valve - move to the AirTAC 4V series.
Before ordering this three-station assembly, match five points: port (M5 or 1/8 in), thread (PT is the standard on 3V1; G and NPT are order options), coil voltage, electrical entry (DIN plug or flying lead), and valve count - an individual unit or a 1 to 20 station manifold.
Confirm before you order
Pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, IP65 coil protection (DIN 40050). Coil power by voltage: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W - this assembly uses DC24V. The 3/2 function is direct-acting, single solenoid, spring return. No Cv or effective area is published for 3V1; confirm flow from the datasheet or our RFQ desk.
A 3/2 valve has three ports and two states, so each station either feeds its line or vents it. That covers single-acting spring-return cylinders, clamps, air blow and piloting larger valves - but not double-acting cylinders, which need a 5-port valve from the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.