AirTAC 3V1 · 3/2-Way Solenoid Valve

AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F)

The AirTAC AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageAC110V
  • Electrical entryDIN plug (DIN socket type)
  • Stations18
  • Series3V1
$353.28 $365.73Save 3% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F)

Eighteen stations on one gallery: 3V106C18F is a near-full 3V1 bank, eighteen 3/2 direct-acting, spring-return valve positions sharing a single PT1/8 manifold. At 4.5 VA per AC110V coil, eighteen of them together present a total draw that is still easy on the control transformer. The valves are supplied in a single fixed initial state - confirm it on the datasheet.

Mounting eighteen valves in series removes the tees, nipples and interconnecting pipework an eighteen-body hard-plumbed panel would need. Each position retains its own manual override for setup and its IP65 (DIN 40050) protection, with media limits of 0-0.8 MPa and -20 to 70 C on air filtered to 40 um or finer.

AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F) Technical Specifications

ModelAirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F)
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageAC110V
Electrical entryDIN plug (DIN socket type)
Coil power4.5 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F)

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
18F18 stations in one assembly.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F) Is Used

settings_input_component

Parcel-sorter gate array

Fires eighteen spring-return gates along a parcel sorter, each valve switching its own ram from the common manifold gallery.

factory

Washdown purge header

Feeds a header of purge and rinse jets inside an IP65-rated food-plant washdown cabinet, matching the valve's own ingress protection.

speed

Press-cell quick clamps

Sequences quick-release clamps around a press-loading cell, where spring return drops every clamp the instant control power fails.

Is the AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F) the Right Part?

At 18 of the maximum 20 stations, this is close to a complete 3V1 bank; check that every circuit is genuinely low-flow, because 3V1 carries no published Cv or effective-area figure. Where a duty needs more, 3V2 (1/8 and 1/4, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4, Cv 0.62) give a step up in flow, while 3V2M suits layouts where manifold density beats flow. Double-acting cylinders require a 5-port valve - the AirTAC 4V series covers those.

Lock down five choices before ordering: port (M5 or 1/8), thread (PT standard, G or NPT to order), coil voltage, entry style (DIN plug or flying lead) and station count, 1F to 20F.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F) FAQ

Each station: 3/2 direct-acting, spring return; 0-0.8 MPa (0-114 psi); -20 to 70 C; IP65 (DIN 40050); AC110V coil at 4.5 VA (family range AC220V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W). No Cv is published for 3V1, so treat flow-critical circuits as an RFQ question rather than a datasheet assumption.

Each position is a 3/2 valve with supply, outlet and exhaust ports and two states - feed the line or vent it. That fits single-acting cylinders, air blow, clamping and pilot duty for a larger valve. It does not fit double-acting cylinders, which need a 5-port valve such as the AirTAC 4V series; air must be filtered to 40 um or finer.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V106C-18 Solenoid Valve, 3V1 Series (3V106C18F)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106C18F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.