verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106CI

The AirTAC Airtac 3V1 Solenoid Valve 3V106CI is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageAC110V
  • Electrical entryFlying lead (lead-out wire type)
  • Series3V1
$24.11 $28.40Save 15% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106CI

3V106CI is an AirTAC 3V1 body solenoid valve in the 1/8in port size, fitted with an AC110V coil drawing 4.5 VA and supplied with pre-wired flying leads instead of a DIN socket. As a direct-acting 3/2-way valve it switches a single line between feed and exhaust: one state supplies the outlet, the other vents it, and the spring return gives a defined de-energised position without a second coil.

That single-line switching suits spring-return cylinders, clamps, on-off air blow and pilot duty on larger process valves. The 4.5 VA coil keeps control-cabinet load low, and the lead-out wiring speeds connection where a plug-in connector is awkward. A manual override is fitted to help set-up and commissioning.

Airtac 3V1 Solenoid Valve 3V106CI Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106CI
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageAC110V
Electrical entryFlying lead (lead-out wire type)
Coil power4.5 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106CI

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106CI Is Used

precision_manufacturing

Ejector on a blister packer

Feeds and vents a small single-acting eject cylinder on a pharmaceutical blister packing line, with the AC110V coil wired straight into the machine control panel.

valve

Pilot stage on a bottling line

Supplies a pilot signal to a larger pneumatic process valve controlling rinse flow, with the spring return venting the pilot line whenever power is lost.

air

Blow-off over a filling head

Switches a short blast of shop air that clears dust from a filling nozzle between cycles, at the low 4.5 VA draw an AC110V control circuit expects.

Is the Airtac 3V1 Solenoid Valve 3V106CI the Right Part?

Start from the port and the duty. 3V1 is the smallest, lowest-power body in the AirTAC 3V range, but no Cv is published for it, so if your duty is flow-critical, confirm sizing with us before ordering. When more flow is needed, step up to 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4in, Cv 0.62); 3V2M is the better pick when dense manifold mounting matters more than flow.

Before you buy 3V106CI, match five points: 1/8in port with PT thread (G or NPT are catalogue options to order), the AC110V coil, the flying-lead entry, and whether you want this individual valve or a 1F-20F manifold assembly. If you must drive a double-acting cylinder, move to the AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106CI FAQ

It is a direct-acting, single-solenoid, spring-return 3/2 valve in a PT1/8in port size. Operating pressure is 0-0.8 MPa (0-114 psi), medium temperature -20 to 70 C, protection IP65 to DIN 40050. The AC110V coil draws 4.5 VA and the connection is a flying lead. Air must be filtered to 40 um or finer. No flow coefficient (Cv) or effective area is published for the 3V1 body - ask us to confirm flow data if it matters to your duty.

Yes for single-acting, spring-return cylinders, clamps, air blow and pilot duty - a 3/2 valve either feeds the outlet or vents it. It cannot drive a double-acting cylinder, which needs simultaneous feed and exhaust paths; use the AirTAC 4V series there. Note also that the 3V1 range carries no published vacuum rating, so do not specify it for negative-pressure work.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106CI

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106CI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.