The AirTAC AirTAC 3V106E-10 Solenoid Valve, 3V1 Series (3V106E10F) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Order code 3V106E10F is a 10-station manifold assembly: ten 3/2-way direct-acting valve bodies share one 1/8in PT base, cutting ten separate fittings and ten mounting holes down to a single block. Each body carries its own AC24V coil at 5.0 VA with spring return, feeding or venting ten independent single-acting circuits - small cylinders, blow jets, clamps or pilot lines - from one panel footprint.
Every coil meets IP65 (DIN 40050) and connects through a DIN socket, so a failed station swaps out quickly without disturbing its neighbours. The valves run on air filtered through a 40 um or finer element with no lubrication, and each station has a manual override for set-up and fault-finding.
| Model | AirTAC 3V106E-10 Solenoid Valve, 3V1 Series (3V106E10F) |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 5.0 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 10F | 10 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Ten stations each feed or vent one small single-acting pusher in a fixture that sorts PCB carriers lane by lane, all served from a single 1/8in PT manifold base.
Each carousel position gets its own 3/2 station to puff filtered air across a sample port between draws, with spring return guaranteeing the jet closes at power loss.
Solenoid stations flick single-acting diverter gates between lanes; a 5.0 VA coil per station keeps the 24V AC supply budget comfortable across all ten gates.
No Cv is published for the 3V1 body, so treat flow-critical sizing as a question to raise with us before you order. When a station needs more flow than this small body can be trusted with, step up to AirTAC 3V2 (1/8in or 1/4in, NC or NO selectable, Cv 0.18-0.19 and rated for vacuum) or 3V3 (1/4in, Cv 0.62); choose 3V2M instead when manifold density beats raw flow. Before ordering a 10-station block, confirm five things: 1/8in port, PT thread as standard (G or NPT are options to order), AC24V coil, DIN plug entry, and the exact station count. A double-acting cylinder is beyond what any 3-port valve can drive - send that duty to the 5-port AirTAC 4V series.
Confirm before you order
Ten 3/2 direct-acting, spring-return stations on one 1/8in PT base. Operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 (DIN 40050) coils. Coil ratings by voltage: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W; this assembly uses AC24V, so budget for ten 5.0 VA coils. There is no published Cv for 3V1 - ask us about any flow-critical station.
The 3V1 family is manifolded in series from 1F to 20F, so 10F is one point in that range and a different count is ordered as its own SKU. Each station is an independent 3/2 valve that feeds or vents its own line, so it handles single-acting cylinders, blow duty and pilot signals, but never a double-acting cylinder; that calls for the 5-port AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.