AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106FI-X1

The AirTAC Airtac 3V1 Solenoid Valve 3V106FI-X1 is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Series3V1
$24.11 $28.40Save 15% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106FI-X1

3V106FI-X1 is an AirTAC 3V1 3/2-way valve built on the DC12V flying-lead configuration: 1/8in PT port, direct acting, single solenoid, spring return. The valve alternately pressurises and exhausts one outlet, so it drives spring-return single-acting cylinders, clamps, air jets or pilots a larger main valve. The trailing -X1 marks a catalogue build suffix - confirm its exact meaning on the datasheet before ordering.

Commissioning is easier thanks to the built-in manual override, which lets you stroke the valve by hand before the 12 V supply is even connected. The 2.5 W DC12V coil keeps the load on your power supply minimal, and the IP65 (DIN 40050) coil enclosure resists the dust and splashing water found around small machine cells.

Airtac 3V1 Solenoid Valve 3V106FI-X1 Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106FI-X1
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil power2.5 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106FI-X1

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106FI-X1 Is Used

build

Fixture clamp commissioning

Fitters jog a swing clamp or pallet clamp by hand using the manual override during set-up, long before the 12 V PLC output is wired in.

settings_input_component

Pilot stage on large process valves

A small air signal from this 3V1 pilots a bigger diaphragm or cylinder-operated main valve on skid-mounted process and water-treatment equipment.

air

Intermittent cooling air jets

Direct the 3/2 output at a drill bit, glue nozzle or sensor window; the moment the coil drops out, the spring return vents the line automatically.

Is the Airtac 3V1 Solenoid Valve 3V106FI-X1 the Right Part?

Because AirTAC publishes no flow coefficient for 3V1, treat this valve as the compact, low-power choice and verify any flow-critical duty with us first. If the job needs more passage, the 3V2 series offers 1/8in and 1/4in ports with NC or NO selection, Cv 0.18-0.19 and a vacuum rating, while the 3V3 reaches 1/4in with Cv 0.62. Where panel density outranks flow, 3V2M is the manifold-optimised alternative. Double-acting cylinders need the 5-port AirTAC 4V range instead.

Five decisions close an order: 1/8in vs M5 port, PT (the family standard) or a G/NPT option ordered specially, coil voltage - this code fixes DC12V at 2.5 W - plug-in DIN or this SKU's flying lead, and single valve versus manifold station count. Also confirm exactly what the -X1 suffix specifies on the datasheet.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106FI-X1 FAQ

The body is rated 0-0.8 MPa (0-114 psi) and -20 to 70 C with IP65 (DIN 40050) protection. This code's DC12V coil takes 2.5 W; for comparison, the 3V1 family also runs AC220V and AC110V at 4.5 VA, AC24V at 5.0 VA and DC24V at 3.0 W. There is no published Cv or effective area for 3V1 - ask us to check any flow-critical application.

A 12 V coil ties the valve into vehicle batteries, solar-charged supplies and legacy 12 V control systems, while the flying lead removes the need for a separate DIN connector and lands directly on a wired harness. The trailing -X1 is a catalogue build suffix not detailed in the standard listing, so confirm its exact content on the datasheet or in your RFQ to us.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106FI-X1

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106FI-X1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.