The AirTAC Airtac 3V1 Solenoid Valve 3V1M5B10F is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The AirTAC 3V1M5B10F is a ten-station manifold assembly built from ten 3V1 3/2 solenoid valves sharing one M5 port face. Each valve is direct-acting with a single coil and spring return, so it either feeds its outlet or vents it to exhaust - right for single-acting cylinders, air blow nozzles, clamps and pilot duty.
Because ten valves arrive as one assembled unit, panel space and inter-piping drop sharply compared with ten separate bodies. Each DC24V coil draws only 3.0 W, and every station carries a manual override for commissioning. The initial state is fixed at the factory - confirm it on the datasheet.
| Model | Airtac 3V1 Solenoid Valve 3V1M5B10F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | M5 |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 10F | 10 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Spring-return gripper cylinders on an electronics assembly head each need feed-and-vent control; ten stations drive ten grippers from one manifold.
Air knives or nozzles that clear cartons and film webbing switch on and off through the 3/2 valve at each station.
Use individual stations to pilot larger pneumatic valves in a water-treatment or food-line control panel.
3V1 is the smallest, lowest-power body in the AirTAC 3V range, and no flow coefficient is published for it, so treat flow-critical duties as a question for us rather than a guess. When a single valve needs more flow, step up to the 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or the 3V3 (1/4in, Cv 0.62). If manifold density matters more than flow, the 3V2M family is the alternative. If your actuator is double-acting, you need a 5-port valve - the AirTAC 4V series.
Before ordering this ten-station assembly, confirm five points: M5 port, DC24V coil, DIN plug entry, ten stations, and the factory-set initial state (check the datasheet). Individual 3V1 valves and other station counts from 1F to 20F are also available on request.
Confirm before you order
Each station is a 3/2 direct-acting, single-solenoid, spring-return valve rated 0-0.8 MPa (0-114 psi) and -20 to 70 C. The DC24V coil draws 3.0 W; other coil options in the 3V1 family are AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA and DC12V 2.5 W. Protection is IP65 (DIN 40050). No Cv or effective area is published for 3V1.
No. A 3/2 valve has three ports (supply, outlet, exhaust) and two states, so it feeds or vents a single line - suitable for single-acting spring-return cylinders, air blow, clamps and piloting larger valves. Double-acting cylinders need a 5-port valve from the AirTAC 4V series. Also note the 3V1 ships in one fixed initial state - confirm it on the datasheet.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.