The AirTAC Airtac 3V1 Solenoid Valve 3V1M5BI5F is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V1M5BI5F is the densest assembly in this M5 flying-lead set: five 3/2 spring-return valves sharing one base. Energise a coil to feed its outlet; cut power and the spring vents the line, making each station a natural on/off for single-acting cylinders, clamps, air jets or pilot signals.
Five stations on one base replace five separate valves, their fittings and their individual wiring runs. Every DC24V coil draws just 3.0 W and carries an IP65 (DIN 40050) rating, and the manual override on each valve lets you jog every function during commissioning.
| Model | Airtac 3V1 Solenoid Valve 3V1M5BI5F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | M5 |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 5F | 5 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Five clamping points on one fixture plate each get their own spring-return valve, so a single base and one air supply serve the whole clamping bank.
Each station meters a pilot signal to a larger actuated process valve, letting one compact panel sequence several treatment lines in turn.
Retractable jigs, part-blow jets and chip-clearing nozzles around the bench all hang off one five-station M5 manifold, jogged via the manual overrides.
Five M5 stations on one base is about as dense as low-power 3/2 control gets, but 3V1 is a small-port body and its flow coefficient is not published by AirTAC. For duties where flow rules, compare the 3V2 (1/8 or 1/4 port, NC/NO selectable, Cv 0.18-0.19, vacuum capable) and the 3V3 (1/4 port, Cv 0.62); where packing many functions into a small cabinet is the goal, 3V2M exists for exactly that. A 3/2 valve can never reverse a double-acting cylinder - specify the 4V series there.
Because this code spells out M5 port, DC24V coil, flying lead and a 5-station base, only two choices remain open: whether M5 is truly the port you want (1/8 versions come as PT, with G and NPT as order options) and whether five stations is the right count for your fixture bank.
Confirm before you order
Five 3/2 stations on one base; operating pressure 0-0.8 MPa (0-114 psi); temperature -20 to 70 C; five DC24V coils at 3.0 W each, 15.0 W total; IP65 per DIN 40050; air filtered to 40 um or better. AirTAC publishes no Cv or effective area for 3V1 - request it from us if flow is critical.
Each valve is direct acting with a spring return: energise the DC24V coil to feed the outlet, cut power and the spring vents the line. The catalogue supplies 3V1 in a single fixed initial state - confirm it on the datasheet - and a manual override on each station lets you test every function before wiring is finished.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.