The AirTAC Airtac 3V1 Solenoid Valve 3V1M5BI7F is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V1M5BI7F is a seven-station manifold assembly of AirTAC 3V1 3/2 solenoid valves with M5 ports. Each valve is direct-acting with a single solenoid and spring return: energise it and the outlet is fed, cut power and the spring shifts it back so the line vents. That feed-or-vent action suits single-acting cylinders, air blow, clamps and pilot signalling.
The DC24V coil draws only 3.0 W, so a full seven-valve block still loads the supply modestly, and the IP65 (DIN 40050) construction shrugs off dust and splash. Each valve arrives with a pre-wired flying lead in place of a DIN socket, which shortens panel wiring on compact multi-valve assemblies. It is supplied in a single fixed initial state - confirm it on the datasheet.
| Model | Airtac 3V1 Solenoid Valve 3V1M5BI7F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | M5 |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 7F | 7 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Seven valves on one shared manifold drive miniature spring-return grippers and ejector pins across an electronics assembly cell, replacing seven separate mounts with a single M5-port block.
On an older packaging machine, pre-wired flying leads on each DC24V valve let technicians swap a worn valve plate without re-terminating DIN sockets inside a cramped panel.
A pulsed M5 air jet, fed and vented by one valve, clears dust from printed circuit boards just before they enter the conformal-coating booth.
3V1 is the smallest, lowest-power body in the 3V family, and AirTAC publishes no Cv or effective-area figure for it, so any flow-critical M5 duty should be checked with us first. Where you need more throughput, step up to 3V2 (1/8" and 1/4" ports, NC or NO selectable, Cv 0.18-0.19, rated for vacuum) or 3V3 (1/4" port, Cv 0.62). If manifold density matters more than flow, 3V2M is the purpose-built alternative. A double-acting cylinder needs a 5-port valve - specify the AirTAC 4V series instead.
Five checks before you order this assembly: the M5 port, DC24V coil, flying-lead entry rather than a DIN socket, seven stations on the shared manifold, and confirmation that your fittings suit the M5 connection (M5 carries no separate thread code).
Confirm before you order
Operating pressure 0-0.8 MPa (0-114 psi); medium temperature -20 to 70 C; air filtered through a 40 um or finer element, no lubrication needed. Coil power across the 3V1 range: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W - this SKU draws 3.0 W at DC24V. Protection is IP65 (DIN 40050). No Cv or effective-area figure is published for 3V1; confirm flow from the datasheet or send us an RFQ.
Each valve feeds or vents a single line, so it suits single-acting spring-return cylinders, on/off air blow, clamping and pilot signalling to a larger valve. It cannot drive a double-acting cylinder - that requires a 5-port valve such as the AirTAC 4V series. With seven valves sharing one base, you replace seven individual mounts with a single block, saving panel space.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.