The AirTAC Airtac 3V1 Solenoid Valve 3V1M5E is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Specified as 3V1M5E, this individual AirTAC valve combines an M5 port with an AC24V coil, the voltage many machine builders reserve for control and safety-side circuits. Functionally it is a 3/2, direct-acting, single-solenoid valve with spring return - energise to feed the outlet, de-energise and the spring vents the line. It is a natural driver for miniature spring-return cylinders, jets, clamps and pilot lines.
The AC24V coil consumes 5.0 VA and seats in a DIN socket for tool-free coil changes. Even at the lowest voltage among the AC options, the valve keeps its IP65 (DIN 40050) seal against dust and splash. Manual override is fitted, letting you jog the valve during commissioning without power on the coil. It ships in one fixed initial state - check the datasheet to confirm which.
| Model | Airtac 3V1 Solenoid Valve 3V1M5E |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | M5 |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 5.0 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
On a Swiss-type turning centre, the valve actuates a miniature spring-return clamp on the bar-feed fixture, wired into the machine's 24V AC control bus at just 5.0 VA.
An M5 air curtain blows chips away from a guarded cutting zone only while the interlock circuit holds, and the spring return kills the jet the moment the guard opens.
In a food plant, the valve pilots a larger process valve admitting steam to a cooking kettle, cycling from the 24V AC control circuit without adding meaningful load to it.
Choose 3V1 for the smallest port and the gentlest footprint in the 3V line-up, but note that no Cv or effective-area figure is published for it - any flow-sensitive M5 application deserves a quick check with us. When the circuit outgrows it, 3V2 gives you 1/8" or 1/4" ports, an NC or NO selectable function and Cv 0.18-0.19, while 3V3 raises the ceiling at Cv 0.62 on 1/4". Where the priority is packing valves tightly rather than flow, look at 3V2M. Double-acting cylinders are a job for the AirTAC 4V series, not this valve.
Confirm five items at order time: M5 port size, the M5 connection (no separate thread code applies at this size), the AC24V coil voltage, DIN-plug entry versus the flying-lead option, and a single valve versus a multi-station manifold.
Confirm before you order
Operating pressure 0-0.8 MPa (0-114 psi) and medium temperature -20 to 70 C. Across the 3V1 series, coil power is AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W - here it is the AC24V coil at 5.0 VA. Protection rating IP65 (DIN 40050); supply air must be filtered to 40 um or better and needs no lubrication. There is no published Cv or effective area for 3V1, so confirm any flow-critical duty from the datasheet or with us.
Machine builders often keep actuators, interlocks and operator devices on a 24V AC control bus for a lower working voltage around personnel. At 5.0 VA this coil adds negligible load to such a bus and still delivers the same 3/2 spring-return function, manual override and IP65 build as every other 3V1 variant. It drives single-acting cylinders, air blow and pilot stages; a double-acting cylinder would need the 5-port AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.