AirTAC 3V110 · 3/2-Way Solenoid Valve

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM)

The AirTAC AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryDIN plug (DIN socket type)
  • Series3V110
$30.93 $35.38Save 12% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM)

Every configuration choice on the 3V11006NCA-AM is decodable from the code: a 3/2 valve, 1/8in port, normally closed, AC220V coil. In use that means the outlet receives no air until the solenoid is energised, and vents it the moment power is removed - behaviour machine designers rely on for release-on-power-loss and stop-on-power-loss duties. The 1/8in port suits small spring-return actuators and short blow lines.

It is a genuine AirTAC part. Elsewhere in the 3V1 family you will find normally open variants, coils in five voltages, flying-lead entry instead of the DIN plug, and manifold bases that carry several valves on one shared supply. Rather than quote numbers we cannot verify, we confirm pressure, flow and coil power from the datasheet when you send an RFQ.

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM) Technical Specifications

ModelAirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM)
Series3V110
Valve type3/2-way (3-port, 2-position)
Initial stateNormally closed
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryDIN plug (DIN socket type)
Coil powerConfirm from the datasheet — ask us
Operating pressureConfirm from the datasheet — ask us
Flow coefficientConfirm from the datasheet — ask us
TemperatureConfirm from the datasheet — ask us
ProtectionConfirm from the datasheet — ask us
We do not publish figures we cannot stand behind. We stock this code and ship it as a genuine AirTAC part, but we do not hold a specification sheet for the 3V110 family. Operating pressure, flow, coil power, protection rating and temperature are therefore not printed here — send us the model and we will confirm them from the factory datasheet, usually within 7-8 hours.

Model Code: AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM)

3V110Body.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM) Is Used

factory

Packaging machine air gate

Supplies a single-acting gate or diverter on a packaging machine, dropping it safely by venting whenever machine power is cut.

valve

Process valve actuation

Drives the spring-return actuator of a small pneumatic process valve, so the process valve closes and vents on control power failure.

engineering

Test rig clamping

Clamps a workpiece in a leak-test or pressure-test rig, with the NC state making sure the clamp lets go the instant the rig is de-energised.

Is the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM) the Right Part?

This configuration - normally closed, 1/8in, AC220V, DIN plug - fits duties where the outlet must vent on power loss and the panel supplies 220V AC. If your fail-safe logic is reversed, a normally open version of the same body exists. Port sizes step from M5 to 1/8in (here), 1/4in and 3/8in; a larger port suits a larger spring-return cylinder. Coils are wound for one voltage each, so AC220V cannot be converted by rewiring. Ask us to confirm sizing from the datasheet before you commit - and if your project needs published flow and coil-power figures on day one, the 3V2 and 3V3 bodies are the documented route. A double-acting cylinder is a job for the AirTAC 4V 5-port series, not for any 3/2 valve.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM) FAQ

Operating pressure, flow and coil power - the numbers this page deliberately leaves out. Request them through the RFQ and we will return them from the AirTAC datasheet. Where a published figure is needed on day one, the 3V2 and 3V3 bodies are the documented alternative.

No. A solenoid coil is wound for one supply voltage and cannot be changed by rewiring, so an AC220V coil needs a 220V AC supply. The same body is offered with AC110V, AC24V, DC24V and DC12V coils across the family - tell us your panel voltage and we will quote the matching variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCA-AM)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V11006NCA-AM and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.