The AirTAC Airtac 3V2 Solenoid Valve 3V208NCAI is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The I at the end of 3V208NCAI changes the electrical entry: this AC220V coil arrives with a pre-wired lead-out instead of the DIN socket, so the installer lands the wires on terminal points or through a grommeted panel rather than plugging a connector. Function is unchanged - a 3/2 direct-acting poppet valve, spring return, normally closed, so the 1/4in outlet stays vented until energised.
Flow is 3.4 mm2 effective area (Cv 0.19) per port, coil power is 7 VA, and the coil housing is rated IP65. The body is also vacuum-capable to -102.2 kPa, a rating missing from the 3V1 and 3V2M families. Manual override is fitted for setup checks. Every unit is genuine AirTAC, supplied against your RFQ.
| Model | Airtac 3V2 Solenoid Valve 3V208NCAI |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | AC220V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC220V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Food and washdown panels favour leads over connectors; the flying lead-out lands directly on terminal strips inside the sealed enclosure, preserving the IP65 rating of the coil housing.
Routes house vacuum to a filtration rig on demand; the -102.2 kPa rating covers negative-pressure lines, so one valve type serves both vacuum and pressure circuits on the bench.
Drives the single-acting cylinder that presses the sealing jaw on a bagging machine; loss of supply vents the line and the return spring lifts the jaw clear of the product.
Match five things to the code: 1/4in port and PT thread (G or NPT can be ordered), normally closed state, AC220V coil, flying-lead entry - and vacuum, which this body accepts between -102.2 kPa and 0.1 MPa. Choose the DIN version (3V208NCA) if technicians prefer a replaceable plug; keep the I suffix where leads are wired into a junction box or panel loom.
For sizing, the honest step up in flow is 3V3 at Cv 0.62, not another 3V208 - the 0.18 to 0.19 jump from 1/8in to 1/4in is nearly nothing. Step down to 3V1 for light duty at 3.0 W on DC24V, or to 3V2M when a multi-station manifold matters more than flow (Cv 0.1). Double-acting cylinders go to the 4V series.
Confirm before you order
Full set in one place: the 3V208 body gives 3.4 mm2 effective area (Cv 0.19) per port, while the 1/8in 3V206 gives 3.2 mm2 (Cv 0.18). Pressure range is 0-0.8 MPa with vacuum service rated -102.2 kPa to 0.1 MPa. Media temperature is -20 to 70 C. Coil power is 7 VA on AC coils and 7.0 W on DC coils, and protection is IP65 (DIN 40050).
NC means no air reaches the outlet until the coil is energised - fail-safe venting for clamps, jaws and blow guns if power drops. If the process needs air to flow while de-energised, order the NO variant instead; both states exist in this series. Neither variant can drive a double-acting cylinder - that requires a 5-port AirTAC 4V valve.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.