The AirTAC Airtac 3V2 Solenoid Valve 3V208NCBI is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V208NCBI pairs the DC24V coil with a flying-lead entry: instead of a DIN socket, pre-wired leads exit the coil housing for direct termination into a junction box, vehicle loom or machine harness. That makes the valve a natural fit on battery-powered and mobile equipment running a 24 V rail, where connectors can work loose under vibration.
The valve itself is a 3/2 direct-acting poppet with spring return, normally closed: the 1/4in outlet is vented until energised. Flow is 3.4 mm2 (Cv 0.19) per port, coil draw 7.0 W, protection IP65. Vacuum duty is within scope at -102.2 kPa to 0.1 MPa - a capability the 3V1 and 3V2M lack. Supplied as genuine AirTAC.
| Model | Airtac 3V2 Solenoid Valve 3V208NCBI |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A 24 V vehicle battery drives the coil to extend a spring-return ram on the lift; hard-wired leads survive road vibration better than plug connectors, and switching off vents the ram.
Vacuum cups lift flat cardboard blanks onto a forming station; the valve switches the vacuum leg, rated down to -102.2 kPa, under direct 24 V PLC control.
Normally closed keeps the compressed-air blow header shut between cycles; the controller energises the valve to fire a cleaning pulse onto the filter bags, then vents the line again.
Before ordering, tick off the five variables: 1/4in port with PT thread as standard (G or NPT to order), normally closed initial state, DC24V coil, flying-lead entry, and vacuum in the duty - accepted here. If a plug connector is preferred, the plain 3V208NCB is the DIN twin of this model.
For more flow, jump to 3V3 (Cv 0.62 on 1/4in, also vacuum-rated); within 3V2 the gain from 1/8in to 1/4in is only 0.18 to 0.19 in Cv. For lighter duty, 3V1 trims coil power to 3.0 W on DC24V against 7.0 W here, and 3V2M wins on manifold density (Cv 0.1). Double-acting actuators need the 5-port AirTAC 4V series.
Confirm before you order
Effective area 3.4 mm2 (Cv 0.19) per port on this 1/4in body; the 1/8in 3V206 measures 3.2 mm2 (Cv 0.18). Operating pressure 0-0.8 MPa, vacuum rating -102.2 kPa to 0.1 MPa, temperature -20 to 70 C, coil power 7 VA (AC) or 7.0 W (DC), and IP65 (DIN 40050) protection.
As a 3/2 valve it either feeds or vents one line, so it fits single-acting spring-return cylinders, clamps, air blow, vacuum switching and pilot duty on larger valves. It cannot drive a double-acting cylinder, which needs pressurisation on both sides - specify the AirTAC 4V series for that.