The AirTAC Airtac 3V2 Solenoid Valve 3V208NOB is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
This is the DC24V DIN-plug version of the AirTAC 3V208 in its normally open form. As a 3/2-way valve it has three ports and two states: in the rest position the 1/4in inlet is already connected to the outlet, and energising the coil shuts the flow and vents the downstream line to exhaust. A spring returns the poppet the moment power is cut, so the de-energised condition is always the open one.
The coaxial poppet is direct-acting, so it needs no minimum pressure to seal and works from 0 to 0.8 MPa. Flow through each port is Cv 0.19 with a 3.4 mm2 effective area, and because the coil draws only 7.0 W on DC24V it suits battery-fed or low-voltage control panels. The valve is also rated for negative pressure down to -102.2 kPa, so the same body can switch vacuum circuits.
| Model | Airtac 3V2 Solenoid Valve 3V208NOB |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
On a bottling line the nozzles must blow continuously and stop only when the PLC commands it - the NO rest state keeps air flowing to the jets until the DC24V coil is energised.
A bank of spring-return clamps that must sit open by default can be fed through this valve; energising the 24V coil vents the clamp line and lets the springs drop the arms.
A larger actuated diaphragm valve on a filtration skid needs a small, reliable pilot; the 1/4in port and Cv 0.19 give enough volume to stroke the actuator briskly.
Match five points before ordering: 1/4in port with PT thread as standard (G and NPT are order options), normally open initial state, DC24V coil, DIN plug entry, and whether the duty includes vacuum. Size down to the 3V1 when the flow is small and coil power matters more - its DC24V coil takes 3.0 W against the 7.0 W here. Choose the 3V2M only when a dense multi-station manifold outweighs flow, since its base routing drops Cv to about 0.1. Step up to the 3V3 (Cv 0.62, also vacuum-rated) when the line needs far more than this valve passes. A double-acting cylinder cannot be run from any 3-port valve - that needs a 5-port AirTAC 4V.
Confirm before you order
Both port sizes share one set of figures: the 1/8in 3V206 gives 3.2 mm2 effective area and Cv 0.18 per port, the 1/4in 3V208 gives 3.4 mm2 and Cv 0.19. Pressure range is 0-0.8 MPa, and the valve is vacuum-rated to -102.2 kPa to 0.1 MPa. Working temperature is -20 to 70 C. Coils take 7 VA on AC and 7.0 W on DC, and protection is IP65 (DIN 40050).
Pick normally open when the outlet must receive air while the coil is off - continuous blow, purge or a fail-open vent - and switch flow off by energising. NC is the opposite: no air reaches the outlet until the coil is powered. With this 3V208NOB the DC24V, DIN-plug form is fixed by the ordering code itself, so the code states the whole configuration.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.