The AirTAC Airtac 3V2 Solenoid Valve 3V208NOC is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Specified where 110V AC control circuits are the plant standard, the 3V208NOC is a normally open 3/2 valve with a 1/4in PT port and a DIN-plug coil connection. At rest the inlet is open to the outlet; powering the AC110V coil (7 VA) shuts the flow and vents the outlet port to exhaust, and the spring restores the open state on power loss. That fail-open behaviour is why NO bodies suit purge, blow and release duties.
The direct-acting coaxial poppet seals across the full 0-0.8 MPa range and is also rated for negative pressure, -102.2 kPa to 0.1 MPa, so vacuum lines can share the same valve type. Per-port flow is Cv 0.19 with 3.4 mm2 effective area, and the coil housing meets IP65 (DIN 40050). A manual override is fitted to help during installation and commissioning.
| Model | Airtac 3V2 Solenoid Valve 3V208NOC |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A metrology enclosure needs clean air flowing whenever the machine is idle; the NO valve passes purge air at rest and the AC110V coil interrupts it only during a sealed measurement cycle.
On a process skid this 3/2 pilots a larger spring-return actuator; power off, the actuator line stays fed, and energising the pilot vents it so the spring takes the big valve to its fail position.
A lab filtration manifold holds a vacuum on a Buchner station through the normally open valve; energising the coil breaks the vacuum instantly for fast cake release.
Work through the five match points: 1/4in port with PT thread standard on this family (order G or NPT if the piping is parallel or tapered imperial), normally open rest state, AC110V coil, DIN plug entry, and whether vacuum is part of the duty. Down-sizing: the 3V1 suits light duties at lower coil power (3.0 W on DC24V), and the 3V2M suits dense manifold builds where flow per station is secondary (about Cv 0.1). Up-sizing: the 3V3 in 1/4in reaches Cv 0.62 and is also vacuum-rated when far more flow is needed. If the actuator is a double-acting cylinder, move to the AirTAC 4V 5-port series instead.
Confirm before you order
The 3V208 body in 1/4in gives Cv 0.19 and 3.4 mm2 effective area per port; the smaller 3V206 in 1/8in gives Cv 0.18 and 3.2 mm2. Pressure envelope: 0-0.8 MPa, plus vacuum duty from -102.2 kPa to 0.1 MPa. Ambient and medium temperature: -20 to 70 C. Coil: 7 VA on AC voltages such as this AC110V, 7.0 W on DC. Enclosure: IP65 (DIN 40050).
Yes - the 3V2 body carries an explicit negative-pressure rating of -102.2 kPa to 0.1 MPa, which the related 3V1 and 3V2M families do not. The direct-acting poppet needs no pressure differential to operate, so it works on hard vacuum as well as on 0-0.8 MPa supply air. Catalogue data does not quote a vacuum flow rate or pump-down time; confirm duty figures from the datasheet before specifying.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.