The AirTAC Airtac 3V2 Solenoid Valve 3V208NOF is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Running from a 12 V battery or a low-voltage control rail, the 3V208NOF lets you switch a 1/4in pneumatic line with the same DC12V supply that powers the vehicle or machine, avoiding a separate 24 V or mains feed. It connects through a DIN plug on top of the coil.
The valve is normally open: supply flows to the outlet until the 7.0 W DC coil is energised, then the spring-return poppet closes it and the outlet vents. Direct acting means it works from 0 MPa up to 0.8 MPa, so it can also sit in a vacuum line rated to -102.2 kPa. Note the modest step in flow versus the 1/8in 3V206 - Cv rises only from 0.18 to 0.19 - so pick this size for port convenience rather than extra capacity.
| Model | Airtac 3V2 Solenoid Valve 3V208NOF |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Supplied from the truck's 12 V battery via the DIN plug, the normally open valve feeds a single-acting door-lock cylinder during transit and vents it when the driver energises the coil at the dock.
On a pneumatic seed drill, the valve opens a purge jet across the seed meter at rest; energising the 7.0 W DC12V coil stops the purge so seed is not blown clear of the row.
A small workshop vacuum clamp fixture uses this valve to open and close suction to the cups; since it works from 0 MPa, it also holds when the pump has drawn the line down to vacuum.
Order by checklist: 1/4in port with PT thread as standard (G and NPT catalogue options), normally open, DC12V coil, DIN plug entry, and any vacuum requirement. Compare before committing: the 3V1 suits light duties at 3.0 W on DC24V, the 3V2M suits tight manifold layouts at the cost of flow (Cv 0.1), and the 3V3 - also vacuum rated - moves to Cv 0.62 when 0.19 is not enough. Keep in mind the 1/8in-to-1/4in step barely lifts Cv, so jumping sizes only really pays off at 3V3. If your actuator is double-acting, you need the 5-port AirTAC 4V series instead.
Confirm before you order
Flow per port is Cv 0.19 / 3.4 mm2 on the 1/4in body, against Cv 0.18 / 3.2 mm2 for the 1/8in 3V206. The valve works across 0-0.8 MPa and down to -102.2 kPa in vacuum duty. Its temperature window is -20 to 70 C. Coil power is 7 VA for AC voltages and 7.0 W for DC, ingress protection is IP65 (DIN 40050), and the medium is air filtered at 40 um or finer.
A 3/2 valve feeds or vents one line, so it is made for single-acting spring-return cylinders, air clamps, blow jets, vacuum circuits and pilot signals to larger valves. It cannot reverse a double-acting cylinder, which needs pressure on both ports alternately - that is a 5-port job for the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.