The AirTAC AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves is a genuine 3V-F manifold base manifold base for 3 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.

  • Valve type3/2-way (3-port, 2-position)
  • Stations3
  • Series3V-F manifold base
$20.30 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves

The 3V200M3FG is a machined manifold base in the AirTAC 3V200 series, drilled for three valve stations fed from one shared air supply. Mounted side by side, three 3/2 solenoid valves draw from a single feed instead of three separate fittings, which cuts pipework, keeps the wiring loom in one place and makes fault-finding a matter of lifting one valve at a time. The base itself carries no coil: it has no voltage, no state and no electrical entry of its own.

We stock the 3V200M3FG as a genuine AirTAC part and supply it with the matching valves ordered separately, so you pick the normally closed or normally open version, the coil voltage and the electrical entry for each station. Across the 3V200 valve series we hold both states, five coil voltages and both DIN plug and flying-lead entries. Because we do not hold a datasheet for this family in-house, any published figure - pressure, flow or coil power - is confirmed for you from the datasheet before you commit to the order.

AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves Technical Specifications

ModelAirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves
Series3V-F manifold base
Item formManifold base (no coil, no solenoid, no initial state)
Stations3
Port sizeConfirm from the datasheet — ask us
ThreadG (BSPP parallel)
Operating pressureConfirm from the datasheet — ask us
Flow coefficientConfirm from the datasheet — ask us
TemperatureConfirm from the datasheet — ask us
ProtectionConfirm from the datasheet — ask us
We do not publish figures we cannot stand behind. We stock this code and ship it as a genuine AirTAC part, but we do not hold a specification sheet for the 3V-F manifold base family. Operating pressure, flow, coil power, protection rating and temperature are therefore not printed here — send us the model and we will confirm them from the factory datasheet, usually within 7-8 hours.

Model Code: AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves

3V-F manifold baseBody.
3F3 stations in one assembly.
G (BSPP parallel)Port thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves Is Used

settings_input_component

Packaging machine control stack

Spring-return clamps and a blow-off nozzle on a carton sealer run from one manifold feed, so a misbehaving station is isolated by swapping a single valve without touching the pipework.

handyman

Workshop clamping fixture

A jig on a drilling table holds workpieces with single-acting clamps fed from one base, letting every station share the same filtered supply and the same drop on the shop floor.

science

Bench-top test rig

A lab rig switching air to a suction cup or a small spring-return actuator uses the third station as room to add another function later without replumbing the supply line.

Is the AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves the Right Part?

Three stations suit a compact panel where a small group of single-acting functions sit together - clamp, blow and vent, for example - all hanging off one feed and one wiring run. Order the base only when you already know how many valves the panel needs; a lone function is more economically served by one individual valve. Choose NC valves where the outlet must go dead on power loss and NO where it must stay live. Match each coil voltage to the panel supply - it is fixed at order and cannot be changed by rewiring.

Sizing is something we confirm rather than quote: published flow figures for this valve family are not in our hands, so send us your actuator details and ask us to check the pairing before you order. If you need a fully specified 3-port valve today, the AirTAC 3V2 and 3V3 bodies carry published flow and coil-power figures. And if your actuator is double-acting, no 3/2 valve will do the job - that needs a 5-port valve from the AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves FAQ

We do not hold a published datasheet for the 3V200 valve family in-house, so no pressure, flow or coil-power number appears on this page. Send your actuator sizes and panel supply with the RFQ and we will confirm every figure from the datasheet before the order is finalised. If you need published figures today, the AirTAC 3V2 and 3V3 valve bodies carry them.

No on both counts. The base is a machined manifold block only - no coil, no voltage, no state - and the three valves are ordered separately. Each station takes a 3/2 valve, which feeds or vents a single outlet; a double-acting cylinder needs two outlet ports, so it calls for a 5-port valve from the AirTAC 4V series instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V200M3FG Manifold Base 3-Station 3/2 Valves

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V200M3FG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.