The AirTAC AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008F-AM) is a genuine 5/2-way single solenoid (spring return) solenoid valve with AM ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V210-08F-AM is a 4V200-body 5/2 single-solenoid valve with a DC12V coil (2.5 W), terminal-box entry and 1/4in PT ports. Energising the solenoid pressurises one side of a double-acting cylinder while exhausting the other; switching the coil off lets the internal spring snap the spool back, so the electrical signal must be held for as long as the rod needs to stay out.
With a 17.0 mm2 effective area (Cv 1.0) it feeds O32-50 mm bores at up to 5 cycles per second, responding in 0.05 s or less. The 1/4in inlet and outlet pair with a 1/8in exhaust port, the aluminium body weighs just 220 g, and the low-draw DC12V coil makes this the pick for battery carts and mobile rigs where only 12 V DC is on board. Genuine AirTAC, shipped with factory traceability.
| Model | AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008F-AM) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 220 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
On electric utility carts and van-mounted air kits, the 2.5 W DC12V coil sips from the starter battery while Cv 1.0 flips a double-acting lift or tailgate-lock cylinder at up to 5 cycles per second.
A 12 V battery bank driving a double-acting ram on a field water-sampler or soil-probe benefits from the 0.05 s response and spring return: cut power and the probe withdraws on its own, no second signal needed.
On an O40 bore pushing roughly 63 kgf at 0.5 MPa, the valve keeps a drill-jig clamp shut for as long as the coil stays energised, releasing the part the instant the signal drops.
Size it both ways: if your cylinder is an O32 bore (about 40 kgf push at 0.5 MPa) and cycles are infrequent, the smaller 4V100 body at Cv 0.6 is the cheaper match; if you drive an O50 bore (98 kgf) or want a quicker stroke, step up to the 4V300 at Cv 1.65. Between single (spring return), double (memory) and 5/3 centre types, choose single-solenoid only when a lost signal should always retract the rod. A single valve can be piped direct or carried on an integrated manifold base.
Reordering? Match five points: 4V200 body, function 10, 1/4in port in PT thread, the coil voltage (DC12V here) and the entry style (terminal box).
Quick checklist
Effective area 17.0 mm2 (Cv 1.0), maximum 5 cycles per second, activating response 0.05 s or less. Working pressure 0.15-0.8 MPa with 1.2 MPa proof pressure, air filtered to 40 um, temperature range -20 to +70 C. The DC12V coil draws 2.5 W, protection is IP65 (DIN40050) with class B insulation, the valve weighs 220 g, and the exhaust port is 1/8in while inlet and outlet are 1/4in PT.
The 2.5 W, 12 V coil runs straight off battery or solar-backed DC supplies found on mobile carts and remote sites, and its low draw suits switching by small relays or PLC transistor outputs. Wiring lands in the standard terminal box; a grommet lead (suffix I) with 0.5 m flying wires is available if you prefer pre-wired connections. Operating pressure is identical across the whole 4V200 coil range at 0.15-0.8 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.