verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI)

The AirTAC AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI) is a genuine 5/2-way double solenoid (memory) solenoid valve with 22008CI ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port size22008CI
  • Effective area17.0 mm²
  • Flow (Cv)1.0
  • Series4V200
$40.70 $48.20Save 15% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI)

This AirTAC 4V220-08CI is a 5/2-way double-solenoid valve that directs compressed air to double-acting cylinders and actuators, using a memory-spool design. When you pulse the AC110V coil, the spool shifts and stays locked in that last-commanded position even if power is completely removed—held by balanced pressure and friction, not by a holding current. This makes it ideal for applications where you want a cylinder to maintain its end-of-stroke state without continuously energizing a coil.

Pre-wired with a 0.5 m flying lead through a DIN-style grommet, the 4V220-08CI simplifies installation in tight cabinets. The valve body delivers a 17.0 mm² effective area (Cv 1.0) and cycles up to 5 times per second, suiting ~O32-50 mm bore cylinders. At 320 g, it is a compact mid-body solution with a sub-0.05-second response time and IP65 protection.

AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI) Technical Specifications

ModelAirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI)
Series4V200 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port size22008CI
Exhaust port22008CI
Effective area (Cv)17.0 mm² (Cv 1.0)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight320 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area17.0 mm²
Flow coefficientCv 1.0
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-22008CIPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI) Is Used

conveyor_belt

Holding a Gate or Diverter

On a packaging conveyor, a 4V220-08CI shifts a diverter gate to the correct lane and holds it there after a short pulse, even through a control-panel power cycle. The memory function prevents the gate from springing back and misdirecting product.

precision_manufacturing

Clamp-and-Hold Fixtures

In an automated assembly cell, the valve pulses a double-acting clamp closed. The spool remains in the clamped position with zero holding current, keeping the part secure while the machine performs a drilling or fastening operation.

handyman

Energy-Conscious Press Actuation

A small pneumatic press uses the 4V220-08CI to extend the tool, then the coil is de-energized. The valve’s memory holds the ram in contact, reducing coil heat buildup and saving energy during long pressing cycles.

Is the AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI) the Right Valve?

Step up to this 4V220-08CI when you need a 5/2 valve that remembers its position without constant power—unlike the single-solenoid 4V210 which springs back on de-energization. The 4V200 body’s Cv 1.0 flow capacity is sized for mid-range double-acting cylinders; if you are driving a very small O10-20 mm bore, the 4V100 series (Cv 0.6) may be a better fit, while large O63-100 mm cylinders or high-speed cycles call for the 4V300 (Cv 1.65).

For a direct replacement, match these five points: 4V200 body size, 5/2 double-solenoid function (20), 1/4-inch PT port, AC110V coil voltage, and grommet-style electrical entry. The pre-wired grommet lead eliminates the need for a separate terminal-box connector, speeding up panel wiring.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI) FAQ

Because this is a double-solenoid memory valve, the spool stays in the position it was last pulsed to. The cylinder will hold its current state—extended or retracted—until the opposite coil receives a signal. It does not require a holding current and is not magnetically latched; the spool is held by friction and balanced pressure.

Yes, functionally it is identical to a terminal-box 4V220-08C, but the electrical entry is different. This CI model comes with a 0.5 m pre-wired flying lead exiting through a DIN grommet, which is convenient for direct connection to a cable duct or when you want to avoid a separate DIN connector. Ensure your machine’s wiring layout can accept a flying-lead entry.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V220-08CI Solenoid Valve, 5/2-way, PT1/4, AC110V, grommet entry (4V22008CI)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V22008CI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.