verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C)

The AirTAC AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with 230C08C ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Closed center
  • Port size230C08C
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$51.14 $58.64Save 12% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C)

The AirTAC 4V230C-08C is a 5/3-way double-solenoid pneumatic directional valve that introduces a precise closed-center position for double-acting cylinders. When both solenoids are de-energized, the spool blocks all ports, trapping air on both sides of the piston to hold the cylinder in place—ideal for applications requiring a mid-stroke stop without drift. This AC110V terminal-box model delivers that hold with a 3.0 W coil and an effective area of 13.6 mm² (Cv 0.8).

Built on the compact 4V200 aluminum body weighing 360 g, this valve suits cylinders in the O32-50 mm range and cycles up to 3 times per second. The spool shifts in 0.05 seconds or less, and the IP65-rated enclosure stands up to washdown and dusty environments. For a genuine AirTAC 5/3 center valve configured for 110 VAC control, this SKU provides a drop-in solution with a locking manual override for setup and troubleshooting.

AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C) Technical Specifications

ModelAirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Closed center
Port size230C08C
Exhaust port230C08C
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-230C08CPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C) Is Used

precision_manufacturing

Mid-Cycle Clamping

In automated assembly fixtures, the closed center holds a clamp cylinder at a precise intermediate position, allowing an operator or robot to reposition a part without releasing grip pressure.

conveyor_belt

Stop-and-Hold Gates

Controls a pneumatic gate on a conveyor line that must stop and hold product flow mid-stroke for inspection or diverting, maintaining position even if the emergency stop circuit cuts solenoid power.

science

Laboratory Positioning

Drives a double-acting actuator on a test fixture that needs to pause at a set point for measurement. The closed center locks the cylinder in place, preventing drift that would skew sensor readings.

Is the AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C) the Right Valve?

Choose the 4V230C-08C when your double-acting cylinder needs a reliable mid-stroke holding position without continuous power. The closed center blocks all ports at rest, so the load stays put—perfect for pause-and-hold sequences in clamping or pressing. If your cylinder is smaller (below O32 mm), the 4V100 series with Cv 0.6 may offer a more economical match; for larger bores or faster cycling above O50 mm, step up to the 4V300 body (Cv 1.65).

When replacing an existing valve, match five points: the 4V200 body size, the 5/3 closed-center function, the 1/4-inch PT port, a 110 VAC coil, and the terminal-box electrical entry. For multi-valve stations, this body mounts directly onto a 4V200 manifold base, simplifying plumbing and reducing leak points across a bank of valves.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C) FAQ

In the de-energized center position, all ports (P, A, B, EA, EB) are blocked. This traps compressed air on both sides of a double-acting cylinder piston, holding the load at its current position. It is not a safety lock—use an external pilot-operated check valve if you need guaranteed load holding for suspended weights.

Yes, the 'C' voltage code designates an AC110V 50/60 Hz coil with a 4.5 VA inrush. It connects via the standard terminal box. Ensure your supply is stable within ±10% of rated voltage to prevent coil burnout or sluggish shifting.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V230C-08C Solenoid Valve, 5/3-way, closed center, PT1/4, AC110V, terminal entry (4V230C08C)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V230C08C and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.