The AirTAC AirTAC 4V230C-08F Solenoid Valve, 5/3-way, closed center, PT1/4, DC12V, terminal entry (4V230C08F) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with 230C08F ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230C-08F is a 5/3-way double-solenoid pneumatic directional valve built on the popular 4V200 mid-body platform. When both solenoids are de-energised, the spool centers and blocks all ports, locking air in the cylinder to hold a double-acting actuator firmly at its mid-stroke position. This closed-center behavior is ideal for applications where the load must not drift when the control signal is removed.
This specific model is configured with a DC12V coil drawing just 2.5 W, making it a good match for mobile or battery-backed control systems. It carries a 1/4-inch PT port size and delivers an effective area of 13.6 mm² (Cv 0.8), suiting double-acting cylinders in the ~Ø32-50 mm range. The aluminum-alloy body weighs 360 g, responds in 0.05 s or less, and is rated IP65 for dusty or wet factory environments.
| Model | AirTAC 4V230C-08F Solenoid Valve, 5/3-way, closed center, PT1/4, DC12V, terminal entry (4V230C08F) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | 230C08F |
| Exhaust port | 230C08F |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -230C08F | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Used to stop a double-acting cylinder at an intermediate position for a precise glue-dispensing or pressing operation. The closed center blocks all ports, holding the tooling in place without consuming solenoid power.
Controls a diverter gate on a conveyor line that needs a hard stop in the middle of its stroke. The 4V230C-08F holds the gate steady against product back-pressure when the solenoid is off.
Positions a sampling arm at a precise intermediate point in a test sequence. The DC12V 2.5 W coil works safely with low-voltage lab power supplies, and the IP65 rating handles occasional wash-downs.
Choose the 4V230C-08F when your pneumatic circuit needs a mid-stroke holding position without continuous solenoid power. The closed center is distinct from the exhaust-center (30E) which lets the cylinder float, or the pressure-center (30P) which pressurises both sides. Ensure the 4V200 body’s 13.6 mm² effective area provides enough speed for your cylinder; for smaller Ø20 mm actuators, the 4V100 series (Cv 0.6) may be more economical, while larger Ø63 mm bores or very fast cycles often benefit from stepping up to the 4V300 series (Cv 1.65).
For a drop-in replacement, match five points: the 4V200 body size, the 5/3 closed-center function (30C), the 1/4-inch PT port, a DC12V coil voltage, and the standard terminal-box electrical entry. This valve can be mounted individually or on a manifold base for multi-valve assemblies.
Quick checklist
When both solenoids of the 4V230C-08F lose power, the spool returns to its center position and all ports (P, A, B, EA, EB) are blocked. This traps compressed air on both sides of the cylinder, holding the piston in its current position. Note that this is not a safety brake—for suspended loads, add a pilot-operated check valve or mechanical lock.
Yes, this specific model (4V230C-08F) is built with a DC12V coil rated at 2.5 W, making it directly compatible with 12 VDC battery systems, mobile equipment, and low-voltage control panels. Ensure your power supply can handle the inrush current when the solenoid is first energised.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.