AirTAC 4V Series · 5/2-way Solenoid Valve

Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A

The AirTAC Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A is a genuine 5/2-way solenoid valve solenoid valve with 430P15A ports and an effective area of See datasheet (Cv —). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSolenoid valve
  • Port size430P15A
  • Effective areaSee datasheet
  • Flow (Cv)
  • Series4V
$275.95 $298.26Save 7% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A

The B03-4V430P15A is AirTAC's explosion-proof build of the 4V430P-15A, a 5/3-way pressure-center solenoid valve with a PT1/2 port. The leading 'B03-' prefix marks this as the hazardous-atmosphere version of the base valve, engineered for flammable environments where standard coils could be a risk. It directs compressed air to double-acting cylinders and actuators, and at its center position both cylinder ports are simultaneously pressurized, which can be useful for balancing or holding a load in a mid-stroke position.

This valve carries the 4V400 body's 5/3 performance class: a 40.0 mm² effective area (Cv 2.35) and a 3 cycle/sec maximum frequency. The AC220V coil draws just 4.5 VA, and the complete unit weighs 770 g. With a response time of 0.05 s or less and IP65 protection, it suits large-bore cylinders in the 80-125 mm range. For the exact explosion-proof protection rating and certification for your zone, please confirm with us - our data does not include the specific Ex marking or certificate number.

Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A Technical Specifications

ModelAirtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A
Series4V solenoid valve (spool type)
Valve type5/2-way
FunctionSolenoid valve
Port size430P15A
Exhaust port430P15A
Effective area (Cv)See datasheet (Cv —)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequencySee datasheet
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
WeightSee datasheet

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective areaSee datasheet
Flow coefficientCv —
Response time≤ 0.05 s
Coil powerAC 3.5–4.5 VA · DC 2.5–3.0 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A

4VSolenoid valve, spool type, 4-series.
BBody size (4V) — sets port & flow.
0Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-430P15APort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4VB10 (single), 4VB20 (double), 4VB30C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A Is Used

settings_input_component

Hazardous-Area Cylinder Control

Operate double-acting cylinders in petrochemical or solvent-handling lines where flammable vapors may be present, using the explosion-proof B03 build to reduce ignition risk.

precision_manufacturing

Pressurized Balancing

Use the pressure-center function to pressurize both sides of a large-bore cylinder, holding a heavy tool or platen in position during setup or dwell phases.

factory

Large-Bore Material Handling

Drive 80-125 mm cylinders in bulk handling equipment where the 40 mm² effective area delivers the force needed for lifting or shifting heavy loads.

Is the Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A the Right Valve?

Choose the B03-4V430P15A when you need a 5/3 pressure-center function on a 1/2-inch port in a potentially explosive atmosphere. The pressure-center behavior is ideal for applications where you want to pressurize both sides of a double-acting cylinder at rest, such as keeping a load balanced or preventing drift in a specific position. The 40.0 mm² effective area (Cv 2.35) is the 5/3 rating for the 4V400 body - if you need more flow, you'd step up to a larger valve series, and for smaller cylinders the 4V300 (Cv 1.65) is the lighter-duty option.

When replacing an existing valve, match these five points exactly: body size (4V400), function (5/3 pressure center), port and thread (PT1/2), coil voltage (AC220V), and electrical entry (terminal box). The B03- prefix is the explosion-proof variant, so confirm the protection level and certification with us before installation in a classified area.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A FAQ

B03- is AirTAC's explosion-proof build of the base 4V430P-15A valve. It is intended for hazardous or flammable atmospheres. Our data does not include the specific protection rating, Ex marking, or certificate number - please confirm those details with us for your particular zone.

At the center position, both cylinder ports (A and B) are simultaneously pressurized. This can help balance a load or hold a double-acting cylinder in position. Note that for guaranteed load holding in a suspended-load scenario, you should add a dedicated mechanical brake or pilot-operated check valve at the cylinder ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B03-4V Explosion-Proof Solenoid Valve B03-4V430P15A

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for B03-4V430P15A and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.