The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR300N15ALJN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR300N15ALJN is a filter and regulator combined into a single body, handling both filtration and pressure control in one compact unit. This model uses a 1/2in port, a lower-pressure range of 0.15-0.4 MPa (20-58 psi), and a 40 um element, with a nylon bowl and automatic drain.
The diversion structure inside spins the incoming air to separate liquid water and solid particles into the 60 cc drain bowl, while the balanced, self-locking regulator keeps the outlet pressure steady as supply varies. Weighing 500 g, this unit replaces a separate filter plus regulator, reducing potential leak points and saving rail space.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR300N15ALJN |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Not included (J) |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-15 (F.R.L. combination) |
Feed a single-station assembly fixture with regulated air at 0.15-0.4 MPa, using the automatic drain to handle condensate without manual intervention.
Provide filtered, lower-pressure air to lab instruments or test benches where precise, low-pressure regulation is required and space is limited.
Supply a secondary circuit on a machine tool, such as a clamping or positioning system, with clean air at a stable lower pressure.
Choose the GAFR300 body for 1/2in port applications needing a 60 cc drain bowl and a flow envelope plotted to 3500 L/min at 0.7 MPa inlet. The nylon bowl offers a different build option compared to PC or metal, with the same 1.0 MPa max pressure and -5 to 70 C rating. This model has an automatic drain for unattended operation, no mounting bracket (J), and no gauge (N) - the 1/8in gauge connection is available if you add one later. The L-type regulator tops out at 0.4 MPa, so verify your system never needs more than that. For lines requiring lubrication downstream, order the matching GAFC300-15 combination instead. The 40 um element handles standard industrial air; select the 5 um option for finer filtration. With PT threads and a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, a lower-pressure range of 0.15-0.4 MPa (20-58 psi), a maximum pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 60 cc drain bowl, and weighs 500 g. The unit uses a 40 um element and has an automatic drain.
The 'N' after the port code means no gauge is supplied - the 1/8in gauge connection is there if you want to add one. The 'J' means the mounting bracket is omitted, which suits panel-mount installations or setups where you already have a bracket. This reduces cost and parts when those accessories are not needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.