The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR40015LJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR40015LJNK is a genuine AirTAC filter & regulator that combines both functions in a single body, saving rail space and reducing potential leak points versus separate units. It handles a 1/2in port with a 100 cc condensate bowl and weighs 880 g, placing it in the mid-size class for machine headers.
This lower-pressure version regulates from 0.15-0.4 MPa (20-58 psi) and comes with a 40 um element. The unit includes both semi-auto and manual drains, and features a reverse-flow valve fitted as an ordering difference. No gauge is supplied, but the 1/4in gauge connection is ready for one.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR40015LJNK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Use the lower 0.15-0.4 MPa range for sensitive pneumatic controls that need a stable, low regulated pressure without the risk of over-pressurization.
Feed a single machine header with 1/2in piping, providing filtered air at a consistent low pressure to multiple actuators from one central point.
Set up test benches where a precise, low-pressure air supply is needed for calibration or component testing, with the 100 cc bowl handling normal condensate.
Choose the GAFR400 body for 1/2in port lines needing up to 7000 L/min plotted flow at 0.7 MPa inlet. The PC bowl suits standard shop air; the included semi-auto and manual drains give flexibility for scheduled maintenance. The L-type regulation tops out at 0.4 MPa, so confirm your system never needs more pressure. The J code means no bracket is included, and the N code means no gauge is fitted. The K code adds the reverse-flow valve as a specified option. If downstream lubrication is required, order the matching GAFC400-15 combination instead. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g.
The N code means no gauge is supplied, but the 1/4in gauge connection is present for adding one later. The J code omits the mounting bracket, so you must use an existing bracket or panel mount. The K code adds a reverse-flow valve as an ordering difference.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.