The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C10L is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C10L is a filter and regulator combined into a single body, so incoming air is spun to separate liquid water and trap solid particles before a balanced regulator sets a steady outlet pressure. This 3/8in unit carries a metal bowl and a 40 um element, with a working range of 0.15-0.4 MPa (20-58 psi) for applications that need a modest, stable pressure.
Weighing 880 g with a 100 cc condensate bowl, this size class suits machine sub-circuits or individual stations rather than whole-plant headers. The pressed-in self-locking knob resists set-pressure drift from vibration, and the circular gauge with clip and magnifier saves panel space while showing the MPa/psi scale.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C10L |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 3/8" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-10 (F.R.L. combination) |
Feed a bank of small pilot valves on an assembly fixture where a steady 0.15-0.4 MPa signal is required and the 40 um element protects fine orifices from particle wear.
Regulate air to a coolant misting nozzle on a CNC lathe, where the metal bowl handles occasional water carryover and the 100 cc capacity extends time between drain checks.
Provide filtered, regulated air to a pneumatic test jig that checks leak rates, using the lower pressure range to avoid over-pressurizing sensitive test fixtures.
Choose the GAFR400 body when 3/8in ports and a 100 cc drain bowl match your station's air demand; its flow curve is plotted to 7000 L/min at 0.7 MPa inlet, which is double the 3500 L/min envelope of the smaller GAFR300. The metal bowl is a build choice for the condensate chamber, while the included mounting bracket suits frame or panel attachment, and the 40 um element covers general shop air. This L-type unit tops out at 0.4 MPa, so confirm your actuators never need more; the semi-auto drain plus manual drain are both fitted for routine service. If the line needs oil downstream, order the matching GAFC400-10 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-10 combination; do not expect an oil mist from this unit.
The GAFR400C10L is a filter & regulator with a 3/8in port, 0.15-0.4 MPa (20-58 psi) working range, 1.0 MPa (145 psi) max pressure, 1.5 MPa (215 psi) proof pressure, and -5 to 70 C temperature range. It has a 100 cc drain bowl, weighs 880 g, uses a 40 um element, and comes with a metal bowl, mounting bracket, and circular gauge.
The L code designates a lower-pressure regulator, capped at 0.4 MPa instead of the standard 0.9 MPa. This suits applications needing a gentle, stable pressure, but if your machine may ever require more than 0.4 MPa, you would need the standard S-type version of this body.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.