The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15ALJNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ALJNWK is a filter and regulator combined into a single body, eliminating the need for separate GAF and GAR units. This 1/2in port model operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi) and uses a 5 um filter element to trap fine particles.
Its metal bowl and automatic drain make it suitable for industrial lines where condensate must be expelled without manual attention. The unit weighs 880 g and its flow curve is plotted to 7000 L/min at 0.7 MPa inlet, giving a clear sizing envelope for machine builders.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ALJNWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that require clean, regulated air at a stable lower pressure. The 5 um element protects fine internal passages from particle wear.
Mount on a machine station where operators cannot manually drain condensate. The automatic drain expels water continuously while the lower pressure range protects sensitive tooling.
Supply a test rig or measurement instrument that needs filtered air at a consistent pressure below 0.4 MPa. The metal bowl handles demanding shop floor conditions.
Choose this GAFR400 when you need a 1/2in port with a 100 cc metal bowl and automatic drain for unattended operation. The L-type pressure range tops out at 0.4 MPa, so verify your system never requires more than that; if it does, select the standard S type instead. The 5 um element suits precision valves or instrument air but will need more frequent service than a 40 um element. No bracket is included (J), so plan for panel mounting or an existing support structure. No gauge is fitted (N), but the 1/4in gauge connection allows adding one later. The reverse-flow (reflux) valve is attached as an ordering difference. If you need lubrication downstream, order the matching GAFC400-15 combination instead. Note that 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, operates at 0.15-0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The metal drain bowl holds 100 cc and the unit weighs 880 g. It uses a 5 um element and has an automatic drain.
The N code after the port means no gauge is supplied, though the 1/4in gauge connection is present for adding one. The J code means the mounting bracket is omitted, which suits installations using existing brackets or direct panel mounting. Both options reduce cost when these features are not needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.