The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15ALNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ALNK is a filter and pressure regulator combined in one body, with no lubricator section. It spins incoming air to separate liquid water and trap solid particles, then delivers a steady outlet pressure through a balanced, self-locking regulator mechanism. This model uses a 1/2in port, a metal bowl, and a 40 um element, with a working range of 0.15-0.4 MPa (20-58 psi).
This 880 g unit with a 100 cc drain bowl is a single replacement for a separate GAF filter plus GAR regulator, eliminating two potential leak points and reducing rail width. The pressed-in self-locking knob resists set-pressure drift from vibration, keeping the outlet stable as supply pressure varies.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ALNK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves on a machining center, where the 0.4 MPa ceiling protects sensitive pilot stages and the 40 um element keeps fine particles out of spool orifices.
Supply a multi-station assembly line with regulated air for clamping fixtures and pick-and-place actuators, relying on the automatic drain to shed condensate during long production runs.
Provide stable low-pressure air to a calibration or leak-test bench, where the self-locking regulator holds the setpoint against vibration from nearby pumps and the 100 cc bowl extends service intervals.
Choose the GAFR400 body for 3/8in or 1/2in port lines needing up to 7000 L/min flow, plotted at 0.7 MPa inlet. The metal bowl suits demanding environments, while the automatic drain handles unattended operation. This L-type unit tops out at 0.4 MPa, so confirm your system never needs more. The bracket is included, but no gauge is fitted - the 1/4in gauge connection is ready for one. The 40 um element handles general shop air, and the reverse-flow valve is fitted as an ordering option. If oil is needed downstream, order the matching GAFC400-15 combination. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g. It uses a 40 um element with a 1/2in port and a 1/4in gauge connection.
The K indicates a reverse-flow (reflux) valve is fitted to the GAFR400C15ALNK. This is an ordering difference from models without the K code. The catalogue defers the valve's function to a separate page, so consult the full datasheet for operational details.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.