The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15ALJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15ALJNK is a filter and regulator combined into a single body, eliminating the need for separate components. It cleans incoming air through a diversion structure that spins out liquid water and solid particles, then delivers a steady outlet pressure via a balanced, self-locking regulator mechanism.
This specific model features a 1/2in port, a lower-pressure range of 0.15-0.4 MPa (20-58 psi), and a standard 40 um filter element. It comes with a nylon bowl, an automatic drain, and a reverse-flow valve fitted, but no gauge or mounting bracket. The unit weighs 880 g.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15ALJNK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Ideal for powering pneumatic clamps on a machining fixture where a consistent, lower pressure is needed to avoid deforming delicate workpieces.
Suitable for supplying clean, regulated air to a laboratory test bench or analytical instrument that requires a stable pressure below 0.4 MPa.
A good fit for a packaging machine's tensioning or guiding cylinders, where the automatic drain reduces maintenance on a line with high moisture content.
Choose this GAFR400N15ALJNK for a 1/2in line where a lower regulated pressure of 0.15-0.4 MPa (20-58 psi) is sufficient. The nylon bowl is a build choice; the automatic drain suits unattended operation. Note the J code means no bracket is included, and the N after the port means no gauge is supplied - the gauge connection is 1/4in if you add one later. The K code indicates a reverse-flow valve is fitted. If you need oil downstream, order the matching GAFC400-15 combination instead. With a maximum supply of 1.0 MPa, this unit offers about 0.6 MPa of headroom above its 0.4 MPa top setting, ensuring stable regulation.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port and a lower pressure range of 0.15-0.4 MPa (20-58 psi). Its maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). The operating temperature range is -5 to 70 C. It has a 100 cc drain bowl and weighs 880 g.
The 'J' indicates that the mounting bracket is not included with this model. The 'K' signifies that a reverse-flow (reflux) valve is fitted to the unit. This is an ordering difference; the bracket would need to be sourced separately if required.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.