The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15LJ is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15LJ is a genuine AirTAC filter and regulator combined into a single body, with no lubricator present. It handles a 1/2in port and delivers a lower pressure range of 0.15-0.4 MPa (20-58 psi), filtering down to 40 um.
This unit features a nylon bowl and comes without a mounting bracket, saving rail space in tight panels. Its balanced regulator mechanism holds the outlet steady as supply pressure varies, and the diversion structure spins air to separate liquid water and solid particles into the 100 cc drain bowl.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15LJ |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Set a stable 0.15-0.4 MPa output for a sensitive pneumatic gripper or a small indexing table, where lower pressure protects delicate workpieces.
Mount this bracket-less unit directly to a panel on a benchtop assembly station, saving space while filtering and regulating air for a single actuator.
Feed a leak-test fixture with clean, regulated air at up to 0.4 MPa, using the 40 um element to keep fine particles out of the test circuit.
Choose the GAFR400 body for a 1/2in port with a 100 cc drain bowl, stepping down from the GAFR500's 108 cc or up from the GAFR300's 60 cc. The nylon bowl suits build preferences; the semi-auto and manual drains are both fitted for flexible servicing. The L-type lower pressure range tops out at 0.4 MPa, so confirm your machine never needs more. This model omits the bracket (J) for panel mounting, keeps the circular gauge with MPa/psi scale, and uses a 40 um element. If oil is needed downstream, order the matching GAFC400-15 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
The GAFR400N15LJ works with air, has a 1/2in port, and a lower pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and temperature range is -5 to 70 C. It has a 100 cc drain bowl and weighs 880 g.
The L code sets the regulated output to 0.15-0.4 MPa for applications that need low, stable pressure. The J code omits the mounting bracket for direct panel mounting or use with existing hardware, saving space in compact builds.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.