The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15LJNW is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15LJNW is a filter and regulator combined into one body, cleaning incoming air and holding a steady outlet pressure without needing a separate filter plus regulator pair. This 1/2in version weighs 880 g and uses a 5 um element, with a lower-pressure range of 0.15-0.4 MPa (20-58 psi) for gentle applications.
The nylon bowl collects condensate from the diversion structure that spins out liquid water and solid particles. With no gauge fitted, the 1/4in gauge connection remains available if you add one later; the semi-auto and manual drains are both included for flexible maintenance.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15LJNW |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that need clean, regulated air at modest pressure. The 5 um element protects fine internal passages, while the lower range keeps actuation gentle.
Supply a laboratory test fixture with filtered air at a stable low pressure. The 100 cc bowl handles condensate from humid shop air, and the semi-auto drain lets you purge manually when needed.
Power a light assembly station's pneumatic tools and small actuators. The 1/2in port delivers adequate flow, and the 880 g body mounts securely on a frame or panel.
Choose the GAFR400 body when your line needs 1/2in ports and a 100 cc condensate bowl, stepping up from the GAFR300's 60 cc bowl for longer intervals between draining. The nylon bowl suits environments where a transparent PC bowl is not preferred, while the 5 um element traps finer particles than the standard 40 um for sensitive equipment. This lower-pressure type tops out at 0.4 MPa, so confirm your supply never needs more; the missing bracket (J) means you must provide your own mounting, and the absent gauge (N) requires adding one via the 1/4in connection to read set pressure. For lubrication downstream, order the GAFC400-15 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, a pressure range of 0.15-0.4 MPa (20-58 psi), a maximum pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 100 cc drain bowl, and weighs 880 g. The element is 5 um, and it includes both semi-auto and manual drains.
The N after the port code means no gauge is supplied, leaving a 1/4in connection for adding one later. The J code means the mounting bracket is omitted, so you must use an existing bracket or panel mount. Both options reduce cost when you already have these components in place.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.