The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15LJWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The AirTAC GAFR400N15LJWK is a filter and regulator combined into a single body, eliminating the need for separate components. This 1/2in unit operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi) and uses a 5 um element to trap fine particles.
Its nylon bowl collects condensate, and the unit ships with both semi-auto and manual drains. The reverse-flow valve is fitted, and the circular gauge displays the outlet pressure on an MPa/psi scale.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15LJWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a 1/2in line to a precision clamping fixture where a stable 0.15-0.4 MPa output is needed for delicate operations. The 5 um element protects sensitive valves from fine particulates.
Supply a laboratory test bench with filtered air at a controlled lower pressure. The nylon bowl and 5 um element suit clean-air applications where standard filtration is insufficient.
Use this unit to protect a machine tool's pilot valves and air logic. The 100 cc bowl handles typical condensate loads, and the semi-auto drain allows quick manual purging during maintenance.
Choose the GAFR400 body for 1/2in porting and a 100 cc drain bowl, stepping up from the GAFR300's 60 cc bowl for longer intervals between drains. The nylon bowl is a build choice; the common 1.0 MPa max and -5 to 70 C rating apply across all materials. This L-type unit tops out at 0.4 MPa, so if your machine may need more pressure, select a Standard type instead. The J code means no mounting bracket is included, and the 5 um element offers finer filtration than the standard 40 um. The PT thread and fitted gauge read in MPa/psi, and the K code adds the reverse-flow valve. If your line needs lubrication downstream, order the matching GAFC400-15 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above this unit's 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, a pressure range of 0.15-0.4 MPa (20-58 psi), a max pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 100 cc drain bowl, and weighs 880 g.
The K code indicates the reverse-flow (reflux) valve is fitted to this GAFR400N15LJWK. It is an ordering difference from models without the K code. The specific function of the valve is detailed in the catalogue's separate section.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.