The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15SNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15SNWK is a filter and regulator combined in a single body, so it cleans incoming air and locks outlet pressure without needing separate parts. This 1/2in unit weighs 880 g and uses a nylon condensate bowl, with a 5 um element that traps finer particles than the standard 40 um grade. It operates from 0.15 to 0.9 MPa (20-130 psi) and includes both semi-auto and manual drains for flexible servicing.
Because the filter and regulator share one housing, there are fewer joints to seal and less rail width compared to a separate GAF filter plus GAR regulator. The balanced mechanism holds the set pressure steady as supply varies, and the pressed-in self-locking knob resists drift from vibration. A reverse-flow (reflux) valve is fitted as an ordering difference, and the gauge connection is 1/4in if you add one later.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15SNWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves on a 1/2in header, where the 5 um element protects fine orifices from particle wear and the balanced regulator keeps outlet pressure stable.
Supply a multi-station machine tool line with clean, regulated air at up to 0.9 MPa, using the 100 cc bowl to handle condensate between scheduled drain checks.
Mount on a test bench or instrument air skid where the 880 g body needs a proper frame bracket, and the 5 um element supports sensitive measurement equipment.
Choose this GAFR400 body for 1/2in lines that need up to 7000 L/min plotted flow at 0.7 MPa inlet, stepping up from the GAFR300's 3500 L/min envelope. The nylon bowl suits environments where you prefer a non-metal build, while the 5 um element handles precision valves or instrument air but requires more frequent service than 40 um. The semi-auto plus manual drain lets you empty the 100 cc bowl on schedule or automatically when pressure drops, and the included bracket simplifies mounting. The standard pressure type covers 0.15-0.9 MPa, and the PT thread gives an MPa/psi gauge scale if you fit a gauge. For lines needing oil downstream, order the matching GAFC400-15 combination instead. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.9 MPa (20-130 psi), with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C and must not freeze. The drain bowl holds 100 cc and the unit weighs 880 g. It uses a 5 um element and has a 1/2in port with PT thread.
The GAFR400N15SNWK combines both filtering and pressure regulation in one body, so it replaces a separate GAF filter plus GAR regulator. It does not add lubrication, so if you need oil downstream, order the matching GAFC400-15 combination which includes a lubricator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.