The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR50020LJK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR50020LJK is a filter and regulator combined into a single body, handling both filtration and pressure control without needing separate units. It serves a 3/4in line with a lower-pressure range of 0.15-0.4 MPa (20-58 psi), a 40 um element, and a circular gauge with MPa/psi scale.
This 950 g unit includes a 108 cc condensate bowl and both semi-auto and manual drains, plus a reverse-flow valve fitted as an ordering difference. The balanced regulator holds the outlet steady as supply varies, while the diversion structure spins air to separate liquid water and solid particles into the bowl.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR50020LJK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a 3/4in header serving multiple pneumatic stations on a production line, where the lower pressure range protects sensitive equipment from over-pressurization.
Regulate air for conveyor control valves in a central cabinet, using the 108 cc bowl to handle condensate over longer shifts between manual drains.
Prepare air for a test rig that requires stable low pressure, with the balanced regulator maintaining setpoint as upstream supply fluctuates.
Choose the GAFR500 body for a 3/4in port with an 8000 L/min flow envelope plotted at 0.7 MPa inlet, stepping down from the GAFR600's 12000 L/min at 0.7 MPa inlet if you need less capacity. The PC bowl suits standard environments, while the J code means no mounting bracket is included, so plan for panel mounting or existing brackets. This L-type model tops out at 0.4 MPa, so confirm your system never needs more than that; the semi-auto and manual drains are both fitted, and the 40 um element handles general filtration. The PT thread gives an MPa/psi gauge scale, and the K code adds the reverse-flow valve, which is named here as an ordering difference only. If you need lubrication downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR50020LJK has a pressure range of 0.15-0.4 MPa (20-58 psi), max pressure of 1.0 MPa (145 psi), proof pressure of 1.5 MPa (215 psi), and temperature range of -5 to 70 C. It has a 108 cc drain bowl and weighs 950 g.
The K code indicates a reverse-flow (reflux) valve is fitted. It is an ordering difference only; the catalogue defers its function to a separate page not included in our data.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.