The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR50020SN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR50020SN is a filter & regulator combining air filtration and pressure regulation in a single body. It handles a 3/4in port and delivers a steady 0.15-0.9 MPa (20-130 psi) outlet, with a 40 um element trapping solid particles. Its 108 cc condensate bowl collects separated water and debris, and the unit weighs 950 g.
This model ships without a gauge, so the 1/4in gauge connection is available for adding one later. The mounting bracket is included, and the semi-auto plus manual drain options provide flexible condensate removal. This single unit replaces the need for separate filter and regulator components, reducing potential leak points and saving rail space.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR50020SN |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR500 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a 3/4in header supplying multiple pneumatic actuators on a medium-sized assembly machine, ensuring clean, regulated air at a stable pressure.
Regulate air for a conveyor line's pneumatic stops and diverters, where consistent pressure is critical for timing and reliable operation.
Mount on a process skid to filter and regulate air for control valves and positioners, providing a clean and stable air supply for instrumentation.
Choose the GAFR500 for 3/4in port applications that need a 108 cc drain bowl and a flow envelope plotted to 8000 L/min at 0.7 MPa inlet. The PC bowl is the standard build; select a metal or nylon bowl if your environment requires it, but confirm compatibility for aggressive surroundings. This model has the semi-auto and manual drains fitted, while the A code specifies an automatic drain for unattended lines. The standard S type covers 0.15-0.9 MPa, and the L type is for lower-pressure needs up to 0.4 MPa. The bracket is included, and the N code means no gauge is supplied, leaving the 1/4in connection open. The 40 um element is standard, with a 5 um option for finer filtration. PT thread is fitted, and the K code adds a reverse-flow valve. If lubrication is needed downstream, order the matching GAFC500-20 combination. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR50020SN is a filter & regulator with a 3/4in port. Its pressure range is 0.15-0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The operating temperature range is -5 to 70 C. It has a 108 cc drain bowl and weighs 950 g.
The N in the model code indicates no gauge is supplied. This is for installations where a panel-mounted gauge is already present or where the set pressure is monitored remotely. The 1/4in gauge connection is still provided, allowing a gauge to be added later if needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.