The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR500N20ALJN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20ALJN is a filter and pressure regulator combined into a single 3/4in body, eliminating the need for separate components. It spins incoming air to separate liquid water and trap solid particles, then delivers a steady outlet pressure within the lower 0.15-0.4 MPa (20-58 psi) range using a 40 um element.
This nylon-bowl unit weighs 950 g and features an automatic drain that clears condensate without manual intervention. The balanced regulator holds the set pressure as supply varies, while the pressed-in self-locking knob resists drift from vibration, making it suitable for fixed installations.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20ALJN |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR500 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a 3/4in header serving multiple pneumatic actuators on a production line, where the lower pressure range protects sensitive downstream components.
Mount on a frame or panel in a workshop to supply filtered air at a stable low pressure to a bank of regulators, with the automatic drain reducing maintenance rounds.
Use in a test bench that requires a clean, regulated air supply below 0.4 MPa, where the 40 um element filters particles before they reach precision valves.
Choose this GAFR500 for a 3/4in line needing lower regulated pressure, as the L type tops out at 0.4 MPa. The nylon bowl suits environments where a lighter alternative to metal is preferred, while the automatic drain handles wet or unattended lines. No bracket is included, so plan for panel mounting or existing supports, and note there is no gauge fitted; the 1/4in gauge connection allows adding one later. The 40 um element handles general workshop air, and the PT thread matches standard local fittings. If oil is needed downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi), with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, drain bowl capacity is 108 cc, and the unit weighs 950 g. It uses a 40 um element and has a 3/4in port.
The N after the port code means no gauge is supplied, leaving a 1/4in connection for adding one if needed. The J code omits the mounting bracket, so you must use existing supports or panel-mount the unit. This reduces initial cost when those accessories are already available.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.