The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR500N20ALJWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20ALJWK is a filter & regulator in a single body, combining a diversion filter with a balanced pressure regulator. It handles a 3/4in port with a lower-pressure range of 0.15-0.4 MPa (20-58 psi) and a 5 um element for fine filtration. This 950 g unit replaces a separate filter and regulator, reducing potential leak points and saving rail space.
The nylon bowl holds 108 cc of condensate, and the automatic drain clears it without manual attention. A circular gauge with MPa/psi scale is fitted, and the reverse-flow (reflux) valve is attached as an ordering difference. The pressed-in self-locking knob resists set-pressure drift from vibration, keeping the outlet stable.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20ALJWK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feeds a bank of precision pneumatic valves on a machine tool, where the 5 um element protects fine orifices and the lower 0.4 MPa range suits delicate actuation.
On a plant air header with frequent condensate, the automatic drain clears the 108 cc nylon bowl without operator rounds, keeping the line dry for downstream equipment.
For a control panel where the bracket is omitted, this 950 g unit mounts directly to the panel structure, feeding a 3/4in manifold with stable lower-pressure air.
Choose this GAFR500 for a 3/4in line needing lower regulated pressure, with the 5 um element for finer particle removal. The nylon bowl suits applications where a lighter build is preferred, and the automatic drain handles wet or unattended lines. The J code means no mounting bracket is included, so plan for a panel mount or existing bracket. The K code adds the reverse-flow valve, and the PT thread gives an MPa/psi gauge scale. If oil is needed downstream, order the matching GAFC500-20 combination instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR500N20ALJWK is a filter & regulator with a 3/4in port, pressure range 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C, 108 cc drain bowl, and 950 g weight. It has a 5 um element, automatic drain, nylon bowl, no bracket, fitted gauge, and reverse-flow valve.
The L type limits regulation to 0.15-0.4 MPa for applications that never need more, and the J code omits the mounting bracket for panel-mount installations. The K code adds the reverse-flow valve as an ordering difference, while the 5 um element provides finer filtration than the standard 40 um.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.