The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X100-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 100mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X100-10B is a double-acting ISO 15552 profile cylinder with a built-in 4M310-10 5/2 solenoid valve, offering a 30.0 mm2 orifice (Cv 1.68). Driven by a DC24V terminal coil drawing 3.0 W with IP65 protection and a 0.05 s response time, it delivers robust thrust, pushing 3927 N at 0.5 MPa. The integrated manifold uses O10 x O6.5 PU tubing to bridge the valve and cylinder ports.
Because the built-in valve operates at 0.15-0.8 MPa, the practical working pressure for this assembled SAIF unit is 0.15-0.8 MPa, despite the bare cylinder rating of 1.0 MPa. The factory setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised. By controlling itself from a single coil signal, this unit eliminates remote plumbing and is ideal for decentralized stations across large machines.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X100-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×100 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a remote valve bank, allowing independent pneumatic control directly at individual machine stations to reduce tubing runs.
Provides up to 3927 N of push force at 0.5 MPa for heavy-duty clamping and holding tasks in fabrication environments.
Integrates the 5/2 valve and cylinder into one assembly, bypassing the spatial limits and plumbing costs of adding separate valves to older machines.
Choose this 100 mm bore when high force is needed; stepping down to an 80 mm bore drops the 0.5 MPa push force to 2513 N. The self-valved SAIF100X100-10B beats a separate cylinder and remote valve by saving panel space, reducing wiring, and simplifying decentralized installations. It features a carbon steel rod and PT tapered threads. Remember that the 5/2 valve routes air but does not lock the load; for true position holding under pressure loss, consider the SAIL lock or BSAI clamp-lock cylinders.
When replacing, match the 100 mm bore, 100 mm stroke, 3/8" cylinder port, 4M310-10 valve with a 3/8" valve port (code 10), DC24V terminal entry, and no -S magnet. Since the stroke is 100 mm, no external side-load guide is required. The base profile cylinder is dimensionally interchangeable per ISO 15552 mounting interfaces.
Quick checklist
The 100 mm bore cylinder pushes with 3927 N and pulls with 3681 N at 0.5 MPa. The built-in 4M310-10 valve has a 30.0 mm2 effective area (Cv 1.68) and a maximum frequency of 4 cycles per second.
No, the 5/2 valve routes air but does not lock the load without live pressure. The DC24V terminal coil (3.0 W, IP65) energises to retract the rod by default, but you can reposition the valve to extend-when-energised, removing the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.