The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X150S-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 150mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X150S-10B is a double-acting profile cylinder dimensionally interchangeable per ISO 15552, featuring a 4M310-10 5/2 solenoid valve mounted directly via a manifold block. It delivers substantial thrust, pushing 3927N and pulling 3681N at 0.5 MPa. This specific SKU integrates a DC24V terminal-entry coil consuming 3.0W, activating in 0.05s or less. While the base cylinder rates to 1.0 MPa, the integrated valve operates at 0.15-0.8 MPa, making 0.15-0.8 MPa the practical working range for the assembled unit.
By controlling itself from a single electrical signal, this model eliminates remote plumbing and saves panel space, making it ideal for decentralized stations across large machines. The manifold connects the valve to the cylinder using O10xO6.5 PU tubing. Note that the valve port is 3/8" while the cylinder port is 1/2". Factory-set to retract the piston rod when the coil is energised, it can be reconfigured to extend-when-energised simply by repositioning the valve. The -S magnet supports CMSE reed and DMSE electronic sensors.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X150S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 150 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×150 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Perfect for large-scale production lines needing heavy actuation at multiple stations without the complexity of remote valve banks.
The built-in 4M310 valve eliminates external tubing, saving critical panel and machine envelope space in tight layouts.
Provides robust 3927N push force for moving heavy pallets or workpieces directly on the production line.
Choose this 100mm bore when an application requires heavy thrust up to 3927N at 0.5 MPa. If your force requirements are lower, stepping down to an 80mm bore yields 2513N push force, reducing air consumption. The SAIF100X150S-10B excels in decentralized installations where running separate valve tubing is costly or space-prohibitive, as the 4M310 valve switches the cylinder directly. Ensure your control system matches the DC24V terminal entry and PT tapered threads. The integrated 5/2 valve routes air but does not lock the load; for position holding, consider the SAIL lock or BSAI clamp-lock cylinder series instead. Replacement requires matching bore, 150mm stroke, 3/8" valve port, DC24V, terminal entry, PT thread, and the -S magnet.
Quick checklist
At 0.5 MPa, this 100mm bore cylinder generates 3927N of push force and 3681N of pull force. The integrated 4M310-10 valve has an effective area of 30.0 mm2 (Cv 1.68), ensuring high flow for fast actuation.
This model uses a DC24V terminal-entry coil consuming 3.0W with an IP65 rating. By default, the factory setting retracts the rod when energised, but it can be reconfigured to extend-when-energised by repositioning the valve. The integrated 5/2 valve holds its position by internal pilot pressure, not a spring.