The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X800S-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 800mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X800S-10B is a double-acting ISO 15552 profile cylinder with a built-in 4M310-10 5/2 solenoid valve, delivering a robust 3927N push force at 0.5 MPa. Equipped with a carbon steel rod and an -S magnet for CMSE reed and DMSE electronic sensors, it features a DC24V terminal coil drawing 3.0W with an IP65 rating and a 0.05s response. Because the cylinder rates to 1.0 MPa but the internal piloted valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa.
By integrating the valve directly on the manifold block via O10xO6.5 PU tubing, it eliminates remote plumbing and saves panel space for decentralized stations. The factory setting retracts the rod when the coil is energised, but you can reposition the valve to extend-when-energised. Note that the 5/2 valve routes air and is not a lock; for load holding, consider SAIL or BSAI types.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X800S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 800 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×800 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates long tubing runs from a central panel by driving heavy 100mm bore actuators directly at the station via a DC24V signal.
Delivers up to 3927N of push force at 0.5 MPa for clamping and pressing heavy components without needing external valve plumbing.
Ideal for upgrading older machines where routing new valve tubing is costly, using the integrated 4M310-10 manifold block to save space.
Choose this 100mm bore if you need maximum thrust (up to 801kgf at 1.0 MPa) and decentralized control without a separate valve bank. Stepping down to a 80mm bore yields 2513N push at 0.5 MPa, which may suffice for lighter loads. This unit uses a PT3/8 cylinder port and a PT 1/2 valve port, so never confuse the two thread sizes during installation. The 4M310-10 valve offers a Cv of 1.68 and a 30.0mm2 orifice, supporting up to 4 cycles per second.
With an 800mm stroke, you must account for side-load conditions; using FA or LB mounting with external guides is highly recommended to prevent rod damage. The DC24V terminal connection provides reliable switching, but remember the air cushion only decelerates near stroke end and does not hold the load without live pressure. For exact replacement, match the 100mm bore, 800mm stroke, 10 valve port, DC24V voltage, terminal entry, PT thread, and -S magnet.
Quick checklist
The 100mm bore generates 3927N push and 3681N pull at 0.5 MPa, reaching 801kgf max at 1.0 MPa. The built-in 4M310-10 valve has a 30.0mm2 orifice with a Cv of 1.68.
No, the 5/2 valve routes air but does not lock the piston. The factory setting retracts the rod when energised and can be reconfigured to extend, but it will not hold a load without live pressure.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.