The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X160-06B is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 160mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X160-06B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. This specific SKU is configured with a DC24V terminal electrical entry coil consuming 3.0 W, a carbon steel piston rod, and PT tapered threading. The built-in valve has an effective area of 14.0 mm2 (Cv 0.78) and uses an O8 x O5 PU tube to bridge the manifold block. Because the valve operates at 0.15-0.8 MPa, the practical working pressure for the assembled SAIF unit is 0.15-0.8 MPa, even though the cylinder body rates to 1.0 MPa.
By controlling itself from a single coil signal, it eliminates the need for a remote valve bank, saving panel space and plumbing. The factory default setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised if your sequence requires it. In the 32mm bore class, it delivers 402N push force at 0.5 MPa and reaches a maximum of 82 kgf at 1.0 MPa.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X160-06B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 160 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×160 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with distributed stations, using a single DC24V signal to actuate the 32mm bore without a remote valve bank.
The integrated 4M210-06 valve and manifold block save valuable panel and footprint space in compact assemblies requiring 402N force.
Perfect for upgrading older lines where running new pneumatic tubing is costly; simply wire the terminal and connect the 1/8" air supply.
Choose this 32mm bore if your application requires up to 402N push force at 0.5 MPa; step up to the 40mm bore if you need 628N. The SAIF32X160-06B is ideal for decentralized stations across large machines where running separate valve tubing is costly and a single DC24V terminal connection is preferred. The valve port is 1/8" (code 06) while the cylinder port is PT1/8". Remember that the 5/2 valve routes air but does not hold the load without live pressure; for true mechanical locking, select the SAIL series. When replacing, match the 32mm bore, 160mm stroke, 1/8" valve port, DC24V voltage, terminal entry, PT thread, and no magnet (-S). Since the 160mm stroke exceeds 300mm, ensure adequate side-load guidance to prevent rod binding.
Quick checklist
The 32mm bore generates 402N push and 345N pull force at 0.5 MPa. The built-in 4M210-06 valve provides an effective area of 14.0 mm2 (Cv 0.78) with a maximum frequency of 5 cycles per second.
The DC24V terminal coil drives the 5/2 valve, which by factory default retracts the rod when energised but can be reconfigured to extend. The valve routes air but does not lock the load without live pressure; for holding, use a SAIL lock cylinder.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.